25 of 36
Indesit
Company
Service Manual UK
English
3. To Check Continuity of Conductivity Sensor & Lead
1. Confirm that the dryer is disconnected from the electricity
supply.
2. Remove the Right Hand Side Panel - see Dismantling
Instructions.
3. Remove the Black (single) wire on module connection J11
4. Test between the removed Black wire and the metal
conductivity sensor inside the drum.
The sensor is part of the air duct moulding inside the drum
cavity, beneath the filter - see photo.
5. The resistance should be less than 1.0 ohm.
Conductivity Sensor