Chimney Connection
MASONRY CHIMNEY
Before using an existing masonry chimney, clean the chimney
and inspect the flue liner to be sure it is safe to use. Make repairs
before attaching the furnace. The connector pipe and fittings you
will need to connect directly to a masonry chimney are shown.
The chimney connection should be as short as possible.
If the connector pipe must go through a combustible wall before
entering the masonry chimney, consult a qualified mason or
chimney dealer. The installation must conform to local fire codes,
and N.F.P.A. 211.
DO NOT CONNECT THIS FURNACE TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
The chimney used for a furnace must not be used to ventilate the
cellar or basement. If there is a cleanout opening at the base of
the chimney, close it tightly.
LISTED FACTORY BUILT CHIMNEY
Carefully follow chimney manufacturer's instructions. Use only a
Listed Residential Type or Building Heating Appliance Chimney.
If your chimney starts at the ceiling (Fig. 7), you will need enough
6" pipe to reach the ceiling.
The top of the chimney must be at least 3 feet above the roof
and be at least 2 feet higher than any point of the roof within 10
feet (Fig. 7).
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up through
the chimney. The amount of draft in your chimney depends on the
length of the chimney, local geography, nearby obstructions and
other factors. Too much draft may cause excessive temperatures
in the appliance. Inadequate draft may cause backpuffing into the
room and ‘plugging’ of the chimney.
“Inadequate draft will cause the appliance to leak smoke into the
room through appliance and chimney connector joints.”
“An uncontrollable burn or excessive temperature indicates ex
-
cessive draft.”
Take into account the chimney’s location to insure it is not too
close to neighbors or in a valley which may cause unhealthy or
nuisance conditions.
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
THIMBLE
6" ELBOW
6" CHIMNEY
CONNECTOR
6" ELBOW
NON-COMBUSTIBLE WALL
Figure 6
Figure 7
Summary of Contents for 1357M
Page 6: ...6 Figure 2 Model 1557M Figure 1 Model 1357M DIMENSIONS OF FURNACE ...
Page 23: ...23 CENTRAL INSTALLATION CENTRAL INSTALLATION ADD ON INSTALLATION ...
Page 25: ...25 INSTALLATION D INSTALLATION E ...
Page 26: ...26 INSTALLATION F INSTALLATION G ...
Page 27: ...27 INSTALLATION H TOP VIEW FRONT VIEW ...
Page 30: ...30 NOTES ...
Page 31: ...31 NOTES ...