Heat Pump Water Heater Installation Guide
Econergy
®
HP Series Water Heater Specifications
General
HP4000LT
Height
520 mm
Width
490 mm
Depth
550 mm
Weight
50 kg
Noise rating @ 1.5m
52 dBA
Circuit Breaker
16 amps
Rated Current RLA
4 amps
Refrigerant
R-134a
Refrigerant quantity
590 gm
Ambient Air Temperature
-5 to 40
°C
Performance Specifications **
HP4000LT
Heat output
3600 W
Rated input
1000 W
Recovery rate
67 L/hr
Efficiency (COP)
3.8 W/W
Water / Connections
HP4000LT
Min Supply Pressure
50 kPa
Max Supply Pressure
800 kPa
Min/Max Inlet Water Temperature
5 - 50
°C
Flow/Return Connections
RP1/2” / 15mm
Condensate Drain
15 mm
Max Total Dissolved Solids
250 mg/L
Max saturation index -
+0.80
Zone 1
3-8 people
Zone 2
2-6 people
**
Rated at EN255 Conditions (15˚C / 15˚C / 60˚C /70%)
(Cold water/ Ambient Air/ Hot Water/70%RH)