Heat Pump Water Heater Installation Guide
Apply 9cc of thermal paste (supplied with Tank Sensor) to the back of the tank
sensor mount and place it in the drilled hole against the inside layer of the cylinder.
Adjust the foam core supplied such that when inserted with the pocket into
the hole it sticks out by at least 10mm. Insert the tank sensor foam core, and
then attach the tank sensor cover using the screws provided. Pilot holes of
3.2mm (1/8”) diameter will need to be drilled for these screws. Plug the tank
sensor into the header marked J4 or Ttl on
the circuit board of the HWB module.
6. Electrical Connections
All electrical connections must be made, by a licensed tradesman, according
to the diagram below. The appliance must be installed in accordance with
AS/NZS 3000:2000. A means for disconnection must be incorporated in the
fixed wiring. A Certificate of Compliance must be issued by the installer.
7. Condensate drain
Condensate drains must be run in the following cases:
a) Where the unit is discharging on a concrete path or other location where
wetness/ mould is not desirable or,
b) Where the unit is located in a ceiling cavity
a) Outdoor Mounting.
Use HPCDF accessory. Remove the rear grille and
mount the HPCDF into the punched hole at the bottom right rear of the water
heater unit. Run PVC to the nearest drain location.
b) Ceiling Mounting.
Use drain fitting assembly supplied with HPCMK. Fit
drain fitting to the tray. Run PVC pressure pipe from drain pan (for ceiling
installs) down to the HWC drain or across to the soffit and down the wall. Do
a leak test with water prior to leaving site.
Outer
steel
layer
C
C
Insulation
Inner
copper
layer
SECTION C-C
5
1
2
4
3
5
4
3
1
2
6
Item No.
Descripton
Part No.
Quantity
1
Hot Water Cylinder Wall
HPX-831
1
2
Tank Sensor Pocket
HPX-811
1
3
6m Sensor
1
4
Sylomer Insulating Core
HPX-832
1
5
Tank Sensor Cover
HPX-821
1
6
Thermal Paste
200ml