Econergy Installation Manual Rev G 240914
© Hot Water Heat Pumps Ltd 2018
12/03/2018
www.econergy.co.nz
13
Heat Pump Water Heater Installation Guide
Installation Procedure
1. Mounting System
a) Outdoor Mounting.
Use accessory HPOMK. Lay the unit on its side using
the cardboard packing as protection. Attach the plastic mounting feet to the
underside of the unit using the cap screws provided.
b) Ceiling Installation.
Use only accessory HPCMK. Mount the ceiling tray
in the roof space in a suitable location. The unit should then be placed on the
drip tray and secured in place using the seismic restraints, which should be
attached to the side of the unit and to the support beams.
Please note: Adequate access and room for service must be allowed for the
tradesperson’s safety and to prevent potential property damage. Any damage
caused to private property due to incorrect installation, including damage
caused whilst rectifying faults, is not covered under warranty.
1.
Ceiling access must be large enough to allow the heat pump to fit
through it easily.
2. A walkway must be installed from the access point to the heat pump.
3. The heat pump must be located on a platform at least 2m x 2m and a
minimum height requirement at heat pump of 1500mm to allow working
room around the heat pump.
4. A light of at least 12W LED must be installed above the heat pump.
c) Wall Mounting.
Use accessory HPWMK. Mount wall brackets using level
onto concrete block wall. Place anti-vibration mounts supplied onto wall
brackets. Screw up into unit using 4x capscrews (supplied).
d) Closed Garage Installations.
Cold air leaving the unit must be ducted to
the outside without loss of air flow. A fresh air supply must also be installed to
ensure that the correct air flow through the heat pump is maintained.
1.
Windows are insufficient for this purpose.
2. Ensure no objects can be placed within 500mm of the heat pump as
this will reduce its efficiency.
3. Allow for drainage of water naturally produced by the cooling coil
(evaporator) from within the heat pump.
Adequate access and space for service must
be allowed for all types of installation
!