Heat Pump Water Heater Installation Guide
Field Wiring Diagram
Hot W
ater Backup and
Status Indicator HPHWB
Ttu - Upper
Tank
Temperature
Hot W
ater
Cylinder
Ttl - Lower
Tank
Temperature
Backup Element
RJ45
Data
Cable
Ttu J5
Ttl J4
240VAC Uncontrolled
240VAC Controlled
To HWC
To HP Unit
Phase
Neutral
Earth
Neutral
Phase
Earth
Heat Pump - Electronics
Enclosure
Heat Pump Isolator
IP56 rating
TPS
Twin Core + Earth min. 2.5mm
²
Low V
oltage Cable
CA
T-5 min .24A
WG
Do not splice
Tank Sensor Cable
Use only Econergy Part
HP-TSC
Main Isolator
ENP
Ttu
& Ttl
sensor plug