8
T
-
L ELECTRIC PANEL (ALLEN BRADLEY)
WIRING INSTRUCTIONS FOR BASIC OPERATION
Typically all functions switches are off unless advanced features are needed. See function
switch setting on page 3 for details.
Attention:
This install requires a 24vac to 120vac transformer and a 24vac relay.
To supply the 120vac needed for the Hot Shot Transmitter to operate, install a 24VAC
to 120VAC step up transformer. These are available to purchase from Hot Shot Systems. Run
two wires from the 24 VAC input on the transformer to terminal #9 and #11 in the T
-
L Allen
Bradley Panel. Then take the 2 wires from the 120VAC output side and run them to the trans-
mitters two 120vac inputs.
INSTALL
a 24vac relay
“
Interface Relay
”
to control the Sensor
input on the transmitter. Control the Interface Relay by running a wire from the Allen Bradley
panel
’
s terminal #1 and #2 to each side of the Interface Relays coil terminals. Run a wire to
connect the COM terminal on the 24vac Interface Relay to the COM input on the transmitter.
Wire up the NO terminal on the 24vac Interface Relay to the ON
-
OFF Input on the Transmitter.
Connect a wire from the Lighting Ground terminal of the Hot Shot to an NEC approved ground
rod.
See diagram below
.