To supply the 120vac needed for the Hot Shot Transmitter to operate run a wire from
the pivot panels terminal #3(
120vac Hot
) to the 120vac Hot terminal on the transmitter. Run
another wire from the pivot panels terminal #9 or #10 (
120vac Neutral
) to the 120vac Neutral
terminal on the transmitter.
To connect the pivot panels well control relay to the Hot Shot Transmitter run a wire
from terminal #15 (PUMP CONTROL NO) to the transmitters ON
-
OFF input terminal. Now
run a wire from terminal #16 (PUMP CONTROL COM) to the transmitters COM input termi-
nal. Connect a wire from the Lighting Ground terminal of the Hot Shot to an NEC approved
ground rod.