background image

23

11) Remove the front panel.

12) Move the flush switch to the “FLUSH” position to drain the remainder of the solution.

13) After the solution is drained, move the flush switch to the “ICE” position.

14) Replace the front panel in its correct position.

15) Open the water supply line shut-off valve and supply water to the reservoir.

16) When the gear motor starts, remove the front panel and turn off the power supply.

17) Drain out all water from the water line. See 2) and 3).

18) Move the flush switch to the “ICE” position and run the icemaker.

19) Turn off the power supply after 30 minutes.

20) Pour warm water into the storage bin to melt all ice, and then clean the bin liner with the

solution.

21) Flush out any solution from the storage bin.

22) Turn on the power supply and start the automatic icemaking process.

IMPORTANT

1. After cleaning, do not use ice made from the sanitizing solution. Be careful

not to leave any solution in the storage bin.

2. Follow carefully any instructions provided with the bottles of cleaning or

sanitizing solution.

3. Never run the icemaker when the reservoir is empty.

Summary of Contents for SRC-10H

Page 1: ...uperior Degree of Reliability www hoshizaki com Model FS 1001MLH C Including Condensing Unit Model SRC 10H Modular Cubelet Serenity Series Hoshizaki America Inc Issued 7 29 2005 Revised 12 27 2005 INSTRUCTION MANUAL ...

Page 2: ...ould attempt to install service or maintain this icemaker No such installation service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual Likewise the owner manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation HOSHIZAKI provides this manual primarily to assist qualified service technicia...

Page 3: ... Supply and Drain Connections 14 8 Timer Setting 15 9 Final Checklist 16 10 Startup 17 11 Preparing the Icemaker for Long Storage 18 III Cleaning and Maintenance 19 1 Cleaning and Sanitizing Instructions 19 a Cleaning Solution 19 b Cleaning Procedure 20 c Sanitizing Solution 21 d Sanitizing Procedure Initial 21 e Sanitizing Procedure Final 22 2 Maintenance Instructions 24 Please review this manual...

Page 4: ... CONDENSING UNIT WILL VOID WARRANTY We reserve the right to make changes in specifications and design without prior notice NOTE Only the MODEL NUMBER is replaced for FS 1001MLH C MODEL NUMBER FS 1001MLH SERIAL NUMBER AC SUPPLY VOLTAGE 115 120 60 1 COMPRESSOR GEAR MOTOR 120V 3 0FLA 1 4HP FAN MOTOR OTHER 120V 0 53A MAXIMUM FUSE SIZE 15 AMPS MAX HACR BREAKER USA ONLY 15 AMPS MAX CIRC BREAKER CANADA O...

Page 5: ...cated on the left hand side of the right side panel MODEL NUMBER SRC 10H SERIAL NUMBER AC SUPPLY VOLTAGE 208 230 60 1 3 WIRE W NEUTRAL FOR 115V COMPRESSOR 208 230V 6 5RLA 46LRA FAN MOTOR 115V 1 3FLA 65W OTHER 120V 0 2A MAXIMUM FUSE SIZE 20 AMPS MAX HACR BREAKER USA ONLY 20 AMPS MAX CIRC BREAKER CANADA ONLY 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI 427PSI LO 230PSI REFRIGERANT 404...

Page 6: ...6 2 Dimensions Connections a FS 1001MLH FS 1001MLH C Unit inches mm ...

Page 7: ...7 b With Storage Bin Unit inches mm ...

Page 8: ...8 c Condensing Unit Model SRC 10H ...

Page 9: ... exposed to the sun or to heat remove the film after the icemaker cools 4 Check that the refrigerant lines do not rub or touch lines or other surfaces 5 See the nameplate on the rear panel and check that your supplied voltage corresponds with the voltage specified on the nameplate 6 This icemaker requires a storage bin The recommended storage bin is HOSHIZAKI ICE STORAGE BIN Model B 500 series 7 T...

Page 10: ...p to allow for removal of the auger 4 Setup 1 Unpack the storage bin and attach the four adjustable legs provided bin accessory to the bottom of the storage bin 2 Position the storage bin in the selected permanent position 3 Place the icemaker on the top of the storage bin 4 Secure the icemaker to the storage bin by using the two braces four bolts and four self tapping screws provided The four bol...

Page 11: ...t b Location The condensing unit must be positioned in a permanent site under the following guidelines A firm and flat site A dry and well ventilated area with 24 clearance on both front and rear for ease of maintenance and service should they be required Normal condenser ambient temperature 4 F to 122 F Temperatures not within this operating range may affect the production capacity of the icemake...

Page 12: ...ensing unit and icemaker should not exceed 30 feet above or 10 feet below the icemaker If the vertical distance between the condensing unit and icemaker is greater than 18 feet a p trap 5 8 OD tubing must be installed in the suction line The p trap must be within 18 vertical feet of both the condensing unit and the icemaker This will ensure sufficient oil return to the compressor b Insulate the tw...

Page 13: ...ove the control box cover 3 Connect the three loose leads in the control box to the power supply Note The white lead must be attached to the neutral line 4 Replace the control box cover and the louver panel in their correct positions Note The icemaker and condensing unit have independent power supply circuits Fig 6 5 Remove the plastic caps protecting the couplings Apply two drops of POE oil to th...

Page 14: ...ceeds 113 PSIG the use of a pressure reducing valve is required Drain outlet for icemaking is 3 4 FPT The icemaker drain piping connections must be made separately from the bin drain piping connections A vented tee connection is required for proper flow The drains must have 1 4 fall per foot on horizontal runs to get a good flow The drains should not be piped directly to the sewer system An air ga...

Page 15: ...etting When installed on a Hoshizaki bin any timer setting is acceptable Increasing the timer setting will allow a higher level of ice in the bin before the ice machine shuts down When installed on a Lancer dispenser designed for cubelet ice the timer setting must remain at 10 seconds For other dispenser applications the ice level at shutoff may need to be adjusted depending on the dispenser agita...

Page 16: ...ater supply is OFF or when the pressure is below 10 PSIG When the proper water pressure is restored the icemaker automatically starts running again 9 Have the compressor hold down bolts and the refrigerant lines been checked against vibration and possible failure 10 Has the bin control switch been checked for correct operation To check use an object to cover the chute opening on the bottom of the ...

Page 17: ... unit is turned off wait for at least 3 minutes before restarting the icemaker to prevent damage to the evaporator 3 In the event of a power failure that is less than 3 minutes in duration the gear motor fuse in the ice machine could blow upon restart If this occurs turn off the machine replace the fuse and wait at least 3 minutes before restarting 1 Clean the storage bin See III 2 Maintenance Ins...

Page 18: ... proper ambient temperature is resumed 1 Run the icemaker with the water supply line shut off valve closed 2 Open the drain valve and blow out the water inlet line by using air pressure 3 Turn off the power supply 4 Remove the front panel 5 Move the flush switch on the control box to the FLUSH position 6 Turn on the power supply and then drain out all water from the water line 7 Turn off the power...

Page 19: ...ing water conditions 2 To prevent injury to individuals and damage to the icemaker do not use ammonia type cleaners 3 Always wear liquid proof gloves to prevent the cleaning and sanitizing solutions from coming into contact with skin a Cleaning Solution Dilute 4 8 fl oz 142 ml of recommended cleaner Hoshizaki Scale Away or LIME A WAY Economics Laboratory Inc with 0 8 gallons 3 l of warm water This...

Page 20: ...he evaporator assembly and the reservoir are filled and the solution starts to overflow into the drain pan Note If there is excess scale on the extruding head fill the evaporator assembly and reservoir as described above then use a clamp on the reservoir hose between the reservoir and evaporator assembly to block flow Pour additional cleaning fluid over the extruding head until the evaporator asse...

Page 21: ...rator assembly and the reservoir are filled and the solution starts to overflow into the drain pan 5 Remove the two thumbscrews securing the proximity switch to the chute assembly 6 Remove the chute assembly from the icemaker 7 Remove the packing at the bottom of the ice chute 8 Remove the three ties and the chute insulation 9 Remove the six wing nuts and two baffles 10 Remove the two thumbscrews ...

Page 22: ...ce produced during this procedure e Sanitizing Procedure Final 1 Remove the front panel and top panel then turn off the power supply 2 Move the flush switch to the FLUSH position 3 Turn on the power supply and drain out all water from the water line 4 Turn off the power supply 5 Remove the strap connecting the spout to the chute assembly 6 Remove the thumbscrews securing the spout and lift it off ...

Page 23: ...water line See 2 and 3 18 Move the flush switch to the ICE position and run the icemaker 19 Turn off the power supply after 30 minutes 20 Pour warm water into the storage bin to melt all ice and then clean the bin liner with the solution 21 Flush out any solution from the storage bin 22 Turn on the power supply and start the automatic icemaking process IMPORTANT 1 After cleaning do not use ice mad...

Page 24: ...Lower Bearing Mechanical Seal Consult with your local distributor about inspection and maintenance service To obtain the name and phone number of your local distributor call Hoshizaki Technical Support at 1 800 233 1940 in the USA 1 Stainless Steel Exterior To prevent corrosion wipe the exterior occasionally with a clean and soft cloth Use a damp cloth containing a neutral cleaner to wipe off oil ...