20
[b] Cleaning Procedure
The cleaning process will remove lime deposits from the water system.
1) Remove the front panel and top panel, then turn off the power supply.
2) Close the water supply line shut-off valve.
3) Remove all ice from the storage bin.
4) Move the flush switch to the “FLUSH” position.
5) Turn on the power supply and drain out all water from the water line.
6) Turn off the power supply.
7) Remove the control water valve by removing the fitting nut and two mounting screws. Do
not lose the packing.
8) Check the control water valve screen for debris and clean as necessary.
9) Replace the control water valve in its correct position.
10) Remove the strap connecting the spout to the chute assembly.
11) Remove the thumbscrews securing the spout and lift it off.
12) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are filled and the solution starts to overflow into the drain pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between the
reservoir and evaporator assembly to block flow. Pour additional cleaning fluid
over the extruding head until the evaporator assembly is completely full.
13) Replace the spout and strap in their correct positions.
14) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on
the reservoir hose in step 9, remove it before operation.
15) Move the flush switch to the “ICE” position, then turn on the power supply. Replace the
top panel and front panel in their correct positions. Make ice using the solution until the
icemaker stops making ice.
Note: Always discard the contaminated ice produced during this procedure.
16) Remove the front panel.
17) Move the flush switch to the “FLUSH” position to drain the remainder of the solution.