PROBLEM
POSSIBLE CAUSE
REMEDY
[1] The icemaker
a) Power Supply
1. “OFF” position.
1. Move to “ON” position
will not start
2. Loose connections.
2. Tighten
3. Bad contacts.
3. Check for continuity and
replace.
4. Voltage too high.
4. Check and get
recommended voltage.
b) Fuse (Inside Fused
1. Blown out.
1. Check for short circuit
Disconnect, if any)
and replace
c) Control Switch
1. “OFF” position.
1. Move to “ICE” position.
2. Bad contacts.
2. Check for continuity and
replace.
d) Bin Control
1. Tripped with bin filled
1. Remove ice.
Thermostat
with ice.
2. Ambient temperature
2. Increase ambient
too cool.
temperature.
3. Set too warm.
3. See “II.2.[d]
CONTROLS AND
ADJUSTMENTS, 5) Bin
Control.”
4. Bulb out of position.
4. Place in position.
5. Bad contacts or leaks
5. Check for continuity and
bulb.
replace.
e) High Pressure
1. Bad contacts.
1. Check for continuity and
Control
replace.
f) Transformer
1. Thermal fuse blown out
1. Replace.
or coil winding opened.
g) Wiring to
1. Loose connections or
1. Check for continuity and
Controller Board
open.
replace.
h) Thermistor
1. Leads short-circuit or
1. See “II.2.[d] CONTROLS
open and High
AND ADJUSTMENTS, 1)
Temperature Safety
Defrost Control.”
operates.
i) Hot Gas Solenoid
1. Continues to open in
1. Check for power off in
Valve
freeze cycle and High
freeze cycle and replace.
Temperature Safety
operates.
j) Water Supply Line
1. Water supply off and
1. Check and get
water supply cycle does
recommended
not finish.
pressure.
2. Condenser water
2. Check and get
pressure too low or off
recommended
and Pressure Control
pressure.
opens and closes fre-
quently to finally operate
High Temperature Safety.
k) Water Solenoid
1. Mesh filter or orifice gets
1. Clean.
clogged and water supply
cycle does not finish.
2. Coil winding opened.
2. Replace.
3. Wiring to Water Valve.
3. Check for loose
connection or open, and
replace.
IV. SERVICE DIAGNOSIS
1. NO ICE PRODUCTION
For mechanical
bin control,
see “II. 4. [c]”
Summary of Contents for KML "F" SERIES
Page 6: ...6 I SPECIFICATIONS 1 KML 250MAH...
Page 7: ...7 2 KML 250MWH...
Page 8: ...8 3 KML 350MAF...
Page 9: ...9 4 KML 350MWF...
Page 10: ...10 5 KML 350MAH...
Page 11: ...11 6 KML 350MWH Beginning serial L00001J ending Serial M20060C...
Page 12: ...12 7 KML 350MWH Beginning serial M30061E...
Page 13: ...13 8 KML 450MAF...
Page 14: ...14 9 KML 450MWF...
Page 15: ...15 10 KML 450MAH...
Page 16: ...16 11 KML 450MWH Beginning Serial L00001D ending Serial M10530B...
Page 17: ...17 12 KML 450MWH Beginning Serial M20531D...
Page 18: ...18 13 KML 600MAF...
Page 19: ...19 14 KML 600MWF...
Page 20: ...20 15 KML 600MRF...
Page 21: ...21 16 KML 600MAH...
Page 22: ...22 17 KML 600MWH Beginning Serial L00001D ending Serial M10115C...
Page 23: ...23 18 KML 600MWH Beginning Serial M10121E...
Page 24: ...24 19 KML 600MRH...
Page 25: ...25 20 CONDENSER UNIT URC 7F Unit mm inches...
Page 26: ...26 SPECIFICATIONS URC 7F...
Page 48: ...48 b KML 250MWH KML 350MWF KML 350MWH KML 450MWF KML 450MWH KML 600MWF KML 600MWH...
Page 49: ...49 c KML 600MRF KML 600MRH...
Page 65: ...65 4 PERFORMANCE DATA a KML 250MAH...
Page 66: ...66 b KML 250MWH...
Page 67: ...67 c KML 350MAF...
Page 68: ...68 d KML 350MWF...
Page 69: ...69 e KML 350MAH...
Page 70: ...70 f KML 350MWH Serial L00001J through M20060C...
Page 71: ...71 g KML 350MWH Beginning Serial M30061E...
Page 72: ...72 h KML 450MAF...
Page 73: ...73 i KML 450MWF...
Page 74: ...74 j KML 450MAH...
Page 75: ...75 k KML 450MWH Serial L00001D through M10530B...
Page 76: ...76 l KML 450MWH Beginning Serial M20531D...
Page 77: ...77 m KML 600MAF...
Page 78: ...78 n KML 600MWF...
Page 79: ...79 o KML 600MRF...
Page 80: ...80 p KML 600MAH...
Page 81: ...81 q KML 600MWH Serial L00001D through Serial M10115C...
Page 82: ...82 r KML 600MWH Beginning Serial M10121E...
Page 83: ...83 s KML 600MRH...