106
MODEL
WATER
"SCALE AWAY"
WATER
SANITIZER
gal.
fl. oz.
gal.
fl. oz.
KML-250
2
10.5
2
1
KML-350
2
10.5
2
1
KML-450
2
10.5
2
1
KML-600
2.5
13.5
2.5
1.25
CLEANING
SANITATION
2. CLEANING PROCEDURE
IMPORTANT
Ensure all components, fasteners and thumbscrews are securely in place
after any maintenance or cleaning is done to the equipment.
WARNING
1. HOSHIZAKI recommends cleaning this unit at least once a year. More
frequent cleaning, however, may be required in some existing water
conditions.
2. To prevent injury to individuals and damage to the icemaker, do not use
ammonia type cleaners.
3. Always wear liquid-proof gloves for safe handling of the cleaning and
sanitizing solution. This will prevent irritation in case the solution contacts
with skin.
1) Dilute recommended amount of cleaner Hoshizaki “Scale Away” or “LIME-A-WAY,”
(Economics Laboratory, Inc.) as indicated below.
2) Remove all ice from the Evaporator and the Storage Bin.
Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after
3 minutes. The defrost cycle starts and the cubes will be removed from the
Evaporator.
3) Turn off the power supply.
4) Remove the Front Panel.
Summary of Contents for KML "F" SERIES
Page 6: ...6 I SPECIFICATIONS 1 KML 250MAH...
Page 7: ...7 2 KML 250MWH...
Page 8: ...8 3 KML 350MAF...
Page 9: ...9 4 KML 350MWF...
Page 10: ...10 5 KML 350MAH...
Page 11: ...11 6 KML 350MWH Beginning serial L00001J ending Serial M20060C...
Page 12: ...12 7 KML 350MWH Beginning serial M30061E...
Page 13: ...13 8 KML 450MAF...
Page 14: ...14 9 KML 450MWF...
Page 15: ...15 10 KML 450MAH...
Page 16: ...16 11 KML 450MWH Beginning Serial L00001D ending Serial M10530B...
Page 17: ...17 12 KML 450MWH Beginning Serial M20531D...
Page 18: ...18 13 KML 600MAF...
Page 19: ...19 14 KML 600MWF...
Page 20: ...20 15 KML 600MRF...
Page 21: ...21 16 KML 600MAH...
Page 22: ...22 17 KML 600MWH Beginning Serial L00001D ending Serial M10115C...
Page 23: ...23 18 KML 600MWH Beginning Serial M10121E...
Page 24: ...24 19 KML 600MRH...
Page 25: ...25 20 CONDENSER UNIT URC 7F Unit mm inches...
Page 26: ...26 SPECIFICATIONS URC 7F...
Page 48: ...48 b KML 250MWH KML 350MWF KML 350MWH KML 450MWF KML 450MWH KML 600MWF KML 600MWH...
Page 49: ...49 c KML 600MRF KML 600MRH...
Page 65: ...65 4 PERFORMANCE DATA a KML 250MAH...
Page 66: ...66 b KML 250MWH...
Page 67: ...67 c KML 350MAF...
Page 68: ...68 d KML 350MWF...
Page 69: ...69 e KML 350MAH...
Page 70: ...70 f KML 350MWH Serial L00001J through M20060C...
Page 71: ...71 g KML 350MWH Beginning Serial M30061E...
Page 72: ...72 h KML 450MAF...
Page 73: ...73 i KML 450MWF...
Page 74: ...74 j KML 450MAH...
Page 75: ...75 k KML 450MWH Serial L00001D through M10530B...
Page 76: ...76 l KML 450MWH Beginning Serial M20531D...
Page 77: ...77 m KML 600MAF...
Page 78: ...78 n KML 600MWF...
Page 79: ...79 o KML 600MRF...
Page 80: ...80 p KML 600MAH...
Page 81: ...81 q KML 600MWH Serial L00001D through Serial M10115C...
Page 82: ...82 r KML 600MWH Beginning Serial M10121E...
Page 83: ...83 s KML 600MRH...