11. REMOVAL AND REPLACEMENT OF THERMISTOR
CAUTION
1. Fragile, handle very carefully.
2. Always use a recommended sealant (High Thermal Conductive Type),
Model KE4560RTV manufactured by SHINETSU SILICONE, Part Code
60Y000-11, or Part Code 4A0683-01 or equivalent.
3. Always use a recommended foam insulation (Non-absorbent Type) or
equivalent.
4. Do not shorten or cut the Thermistor leads when installing it.
1) Turn off the power supply.
2) Remove the panels.
3) Remove the Control Box Cover.
4) Disconnect the Thermistor leads from
the K3 Connector on the Controller Board.
5) Remove the Plastic Cable Ties, Foam
Insulation, Thermistor Holder and
Thermistor. See Fig. 2.
6) Scrape away the old sealant on the
Thermistor Holder and the Suction Pipe.
7) Wipe off moisture or condensation on the Suction Pipe.
8) Smoothly apply recommended sealant (KE4560RTV, Part Code 60Y000-11 or
4A0683-01) to the Thermistor Holder concave.
9) Attach the new Thermistor to the Suction Pipe very carefully to prevent damage to
the leads. And secure it using the Thermistor Holder and recommended foam
insulation.
Fig. 2
Foam Insulation
Thermistor Holder
Thermistor Lead
Cable Tie
Summary of Contents for KML "F" SERIES
Page 6: ...6 I SPECIFICATIONS 1 KML 250MAH...
Page 7: ...7 2 KML 250MWH...
Page 8: ...8 3 KML 350MAF...
Page 9: ...9 4 KML 350MWF...
Page 10: ...10 5 KML 350MAH...
Page 11: ...11 6 KML 350MWH Beginning serial L00001J ending Serial M20060C...
Page 12: ...12 7 KML 350MWH Beginning serial M30061E...
Page 13: ...13 8 KML 450MAF...
Page 14: ...14 9 KML 450MWF...
Page 15: ...15 10 KML 450MAH...
Page 16: ...16 11 KML 450MWH Beginning Serial L00001D ending Serial M10530B...
Page 17: ...17 12 KML 450MWH Beginning Serial M20531D...
Page 18: ...18 13 KML 600MAF...
Page 19: ...19 14 KML 600MWF...
Page 20: ...20 15 KML 600MRF...
Page 21: ...21 16 KML 600MAH...
Page 22: ...22 17 KML 600MWH Beginning Serial L00001D ending Serial M10115C...
Page 23: ...23 18 KML 600MWH Beginning Serial M10121E...
Page 24: ...24 19 KML 600MRH...
Page 25: ...25 20 CONDENSER UNIT URC 7F Unit mm inches...
Page 26: ...26 SPECIFICATIONS URC 7F...
Page 48: ...48 b KML 250MWH KML 350MWF KML 350MWH KML 450MWF KML 450MWH KML 600MWF KML 600MWH...
Page 49: ...49 c KML 600MRF KML 600MRH...
Page 65: ...65 4 PERFORMANCE DATA a KML 250MAH...
Page 66: ...66 b KML 250MWH...
Page 67: ...67 c KML 350MAF...
Page 68: ...68 d KML 350MWF...
Page 69: ...69 e KML 350MAH...
Page 70: ...70 f KML 350MWH Serial L00001J through M20060C...
Page 71: ...71 g KML 350MWH Beginning Serial M30061E...
Page 72: ...72 h KML 450MAF...
Page 73: ...73 i KML 450MWF...
Page 74: ...74 j KML 450MAH...
Page 75: ...75 k KML 450MWH Serial L00001D through M10530B...
Page 76: ...76 l KML 450MWH Beginning Serial M20531D...
Page 77: ...77 m KML 600MAF...
Page 78: ...78 n KML 600MWF...
Page 79: ...79 o KML 600MRF...
Page 80: ...80 p KML 600MAH...
Page 81: ...81 q KML 600MWH Serial L00001D through Serial M10115C...
Page 82: ...82 r KML 600MWH Beginning Serial M10121E...
Page 83: ...83 s KML 600MRH...