2013 ADDENDUM
A. Dip Switch Settings
1) S4 Dip Switch Settings
S4 Dip Switch
Model
Auxiliary Code
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KML-250MAH
B-1 and Later
OFF OFF OFF ON ON ON OFF OFF ON OFF
KML-250MWH B-1 and Later
OFF OFF OFF ON ON ON OFF OFF OFF ON
KML-351MAH
V-1 and Later
OFF OFF OFF OFF OFF OFF ON OFF OFF ON
KML-351MWH TBD
ON OFF ON ON OFF OFF OFF OFF OFF ON
KML-451MAH
B-1 and Later
OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
KML-451MWH B-1 and Later
ON OFF OFF OFF ON ON OFF OFF OFF ON
KML-631MAH
B-1 and Later
ON OFF OFF OFF ON ON OFF OFF OFF ON
KML-631MWH C-0 and Later
ON OFF OFF OFF ON ON OFF OFF OFF ON
KML-631MRH
C-0 and Later
ON OFF OFF OFF ON ON OFF OFF OFF ON
2) S5 Dip Switch Settings
S5 Dip Switch (Do Not Adjust)
Model
Auxiliary Code
Dip Switch No.
1
2
3
4
5
KML-250MAH
B-1 and Later
OFF OFF OFF OFF OFF
KML-250MWH
B-1 and Later
OFF OFF OFF OFF OFF
KML-351MAH
V-1 and Later
OFF OFF OFF OFF OFF
KML-351MWH
TBD
OFF OFF OFF OFF OFF
KML-451MAH
B-1 and Later
OFF OFF OFF OFF OFF
KML-451MWH
B-1 and Later
OFF OFF OFF OFF OFF
KML-631MAH
B-1 and Later
OFF OFF OFF OFF OFF
KML-631MWH
C-0 and Later
OFF OFF OFF OFF OFF
KML-631MRH
C-0 and Later
OFF OFF OFF OFF OFF
1
2
3
4
5
ON
1
2
3
4
5
6
7
8
9
10
ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Harvest Pump Timer (7) (Do not adjust)
Factory Use (8)
S4 Dip Switch
Do Not Adjust
S5 Dip Switch
Refill Counter
(2 through 5)
Float Switch
Selector (1)
A-1
Summary of Contents for KML-451MAH
Page 21: ...21 2 KML 451MWH water cooled ...