23
C. Performance Data
1. KML-451MAH (air-cooled)
70/21
403
183
387
176
355
161
80/27
391
177
366
166
328
149
90/32
387
176
349
158
313
142
lbs./day kg./day
100/38
377
171
340
154
279
127
70/21
80/27
90/32
watts
100/38
70/21
115
0.43
100
0.38
92
0.35
80/27
104
0.39
80
0.30
79
0.30
90/32
100
0.38
64
0.24
60
0.23
gal./day m
3
/day
100/38
83
0.31
63
0.24
56
0.21
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
225
15.8
248
17.5
276
19.4
80/27
243
17.1
279
19.6
305
21.4
90/32
248
17.5
305
21.4
332
23.3
PSIG kg/cm
2
G
100/38
253
17.8
311
21.9
357
25.1
70/21
42
3.0
45
3.2
51
3.6
80/27
44
3.1
49
3.5
55
3.9
90/32
45
3.2
53
3.7
59
4.1
PSIG kg/cm
2
G
100/38
47
3.3
54
3.8
64
4.5
23
23
25
2.7
4.0
3.2
3.6
3.1
2.7
3.7
21
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
917
913
944
970
976
890
908
913
25
28
30
32
941
969
996
1020
28
23
24
27
2.7
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
3.5
3.2
3.6
2.7
TOTAL HEAT OF REJECTION
7,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
Summary of Contents for KML-451MAH
Page 21: ...21 2 KML 451MWH water cooled ...