42
L. Removal and Replacement of Pump Motor
1) Turn off the power supply.
2) Remove the front panel.
3) Remove the three screws and the float switch assembly.
4) Remove the wiring connectors from the pump motor leads.
5) Disconnect the hoses attached to the pump motor assembly.
6) Remove the four screws and the pump motor.
7) Install the new pump, and replace the removed parts in the reverse order of which they
were removed.
8) Turn on the power supply, and check for leaks.
9) Replace the front panel in its correct position.
Summary of Contents for KML-451MAH
Page 21: ...21 2 KML 451MWH water cooled ...