49
[g] STARTER
1) Disconnect the terminals, remove the mounting screw.
2) Install the new starter in the reverse order of the removal procedure.
3) To prevent miswiring, check the terminal numbers and lead wire colors with the wiring
label.
[h] RUN CAPACITOR
1) Disconnect the terminals on the starter and remove the nut securing the run capacitor.
2) Install the new run capacitor in the reverse order of the removal procedure.
3) To prevent miswiring, check the terminal numbers and lead wire colors with the wiring
label.
[i] START CAPACITOR
1) Disconnect the terminals on the starter and remove the nut securing the run capacitor.
2) Install the new run capacitor in the reverse order of the removal procedure.
3) To prevent miswiring, check the terminal numbers and lead wire colors with the wiring
label.
[j] CAPACITOR FOR PUMP MOTOR
1) Disconnect the tab terminals, remove the screw.
2) Install the new capacitor in the reverse order of the removal procedure.