2
[b] KMD-410MWH (water-cooled)
AC SUPPLY VOLTAGE
115/60/1
㩷
AMPERAGE
6.5 A (5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
15 A
MAXIMUM FUSE SIZE
15 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day (kg/day)
70
*440 (200)
423 (192)
392 (178)
Reference without *marks
80
427 (194)
401 (182)
364 (165)
90
423 (192)
*382 (173)
347 (157)
100
414 (188)
373 (169)
315 (143)
SHAPE OF ICE
Crescent Cube
ICE PRODUCTION PER CYCLE
8.2 lbs. (3.7 kg) 416 pcs.
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
680(4.3)
670(3.7)
WATER gal./24HR (gal./100 lbs.)
89(23.2)
120(27.2)
WATER COOLED CONDENSER
552(145)
267(61)
gal./24HR (gal./100 lbs.)
㩷
㩷
EXTERIOR DIMENSIONS (WxDxH)
22-1/4" x 24-1/8" x 24" (565 x 613 x 610 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 128 lbs. (58 kg), Shipping 163 lbs. (74 kg)
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet
1/2" FPT
Cond. Inlet 1/2" FPT
- DRAIN
Outlet
3/4" FPT
Cond. Outlet 1/2" FPT
CUBE CONTROL SYSTEM
Float Switch
HARVESTING CONTROL SYSTEM
Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL
Timer Controlled, Overflow Pipe
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Level Switch with Delay
COMPRESSOR
Hermetic, Model NT6217GKV
CONDENSER
Water-Cooled, Tube in tube type
EVAPORATOR
Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A, 14.1 oz. (400g)
DESIGN PRESSURE
High 427PSIG, Low 206PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out (Internal)
COMPRESSOR PROTECTION
Auto-reset Overload Protector (Internal)
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch
ACCESSORIES - SUPPLIED
N/A
- REQUIRED
Ice Dispenser or Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 -100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG
We reserve the right to make changes in specifications and design without prior notice.