[c] CONTROLS AND ADJUSTMENTS
a) Default Dip Switch Settings
The dip switch is factory-adjusted to the following positions:
S1
Dip
Switch
No. 1 2 3 4 5 6 7 8 9 10
KMD-410MAH
OFF
OFF
OFF
OFF
ON ON ON ON OFF
OFF
KMD-410MWH OFF
OFF
OFF
OFF
ON ON ON ON ON OFF
S2 Dip Switch
* Functions of S2 dip switch nos. 2
through 6 depend on program version.
Do not adjust the S2 dip switch. These must be left in the factory default position, or the unit
will not operate properly.
b) Harvest Timer (S1 dip switch 1 & 2)
Used for adjustment of the harvest timer. The harvest timer starts counting when the
thermistor reads a certain temperature at the evaporator outlet.
Control Board
Program Ver.
S2 Dip Switch No.
1
2
3
4
5
6
KMD-410MAH ON
OFF
ON
OFF
OFF
ON
P00013-02
2.5 or earlier
KMD-410MWH ON
OFF
ON
OFF
OFF
ON
KMD-410MAH ON ON ON
OFF
OFF
ON
3.1
KMD-410MWH ON ON ON
OFF
OFF
ON
KMD-410MAH ON ON ON
OFF
OFF
OFF
P01771-02
3.2
KMD-410MWH ON ON ON
OFF
OFF
OFF