9. WATER VALVE
1) Unplug the icemaker or disconnect the power source.
2) Close the water supply tap.
3) Remove the Top Panel and unscrew the Rear Panel.
4) Disconnect the Tab Terminals.
5) Pinch and lower the Hose Clamp.
6) Disconnect the Rubber Hose from the Water Valve. Put a towel under the Water
Valve to receive water coming out.
7) Turn the Inlet Nut in the arrow direction to remove it from the Water Valve. Do not
lose the Gasket inside.
8) Remove the two mounting screws.
9) Install the new valve in the reverse order of the removal procedure.
10) Tighten the Inlet Nut to a torque of 7.85 N•m (±5%) to prevent water leaks.
11) Open the water supply tap.
12) Plug in the icemaker or connect the power source.
13) Check for leaks.
14) Refit the panels in their correct positions.
Fig. 9
Tab Terminal
Hose Clamp
Inlet Nut
Mounting Screw
Rubber Hose
Summary of Contents for KM-40B
Page 1: ...KM 40B KM 55B KM 80B SELF CONTAINED CRESCENT CUBER SERVICE MANUAL F120 1011 073117 ...
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a KM 40B Europe ...
Page 6: ...2 b KM 40B Singapore ...
Page 7: ...3 c KM 40B Australia New Zealand ...
Page 8: ...4 d KM 40B Philippines ...
Page 9: ...5 e KM 55B Europe ...
Page 10: ...6 f KM 55B Singapore ...
Page 11: ...7 g KM 55B Australia New Zealand ...
Page 12: ...8 h KM 55B Philippines ...
Page 13: ...9 i KM 80B Europe ...
Page 14: ...10 j KM 80B Singapore ...
Page 15: ...11 k KM 80B Australia New Zealand ...
Page 16: ...12 l KM 80B Philippines ...
Page 22: ...18 ...
Page 37: ...33 2 WIRING DIAGRAM a KM 40B Philippines b KM 40B Except Philippines KM 55B ...
Page 38: ...34 c KM 80B ...