54
8. PUMP MOTOR
1) Unplug the icemaker or disconnect the power source.
2) Remove the Top Panel and unscrew the Rear Panel.
3) Disconnect the Connector of the Pump Motor lead.
4) Remove the Water Tank (see “V. 15. WATER TANK”).
5) Remove the ties connecting the Pump Motor discharge outlet and pull off the
Silicone Hose.
Fig. 7
6) Remove the screw securing the Pump Motor. Shift the Case to the center to release
it from the Stopper, and lift off the Pump Motor.
Tie
Silicone Hose
7) Install the new motor in the reverse order of the removal procedure.
8) Plug in the icemaker or connect the power source, and check for leaks.
9) Refit the panels in their correct positions.
Fig. 8
Stopper
Screw
Slide to center
Lift off
Summary of Contents for KM-40B
Page 1: ...KM 40B KM 55B KM 80B SELF CONTAINED CRESCENT CUBER SERVICE MANUAL F120 1011 073117 ...
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a KM 40B Europe ...
Page 6: ...2 b KM 40B Singapore ...
Page 7: ...3 c KM 40B Australia New Zealand ...
Page 8: ...4 d KM 40B Philippines ...
Page 9: ...5 e KM 55B Europe ...
Page 10: ...6 f KM 55B Singapore ...
Page 11: ...7 g KM 55B Australia New Zealand ...
Page 12: ...8 h KM 55B Philippines ...
Page 13: ...9 i KM 80B Europe ...
Page 14: ...10 j KM 80B Singapore ...
Page 15: ...11 k KM 80B Australia New Zealand ...
Page 16: ...12 l KM 80B Philippines ...
Page 22: ...18 ...
Page 37: ...33 2 WIRING DIAGRAM a KM 40B Philippines b KM 40B Except Philippines KM 55B ...
Page 38: ...34 c KM 80B ...