![Hoshizaki KM-40B Service Manual Download Page 32](http://html.mh-extra.com/html/hoshizaki/km-40b/km-40b_service-manual_2164649032.webp)
28
1) Check the dip switch settings to assure that S1 dip switch 3, 4, 7, 8, 9, & 10 and S2
dip switch 1 through 6 are in the factory default position. S1 dip switch 1, 2, 5, & 6 are
cleaning adjustments and the settings are flexible.
2) Move the control switch to the “ICE” position and check for proper control voltage. If
the “POWER OK” LED is on, the control voltage is good. If the “POWER OK” LED
is off, check the control transformer circuit. If no voltage is present, check the power
supply circuit.
3) To perform a relay sequence test, turn on the power switch while pressing the
“OUTPUT TEST” button. The correct lighting sequence should be 5, 6, 7, 8, 9, 4.
Some components (e.g. the compressor) will cycle during test. Each LED flashes
three times in 5 seconds. LED 5 continues to flash while LED 6 flashes. Following the
output test sequence, the icemaker will resume normal operation beginning with the 1
minute fill cycle.
[e] CONTROL BOARD REPLACEMENT
The dip switches should be adjusted to the factory default settings as outlined in this
manual.
4. THERMISTOR
A thermistor (semiconductor) is used as a harvest control sensor and anti-slush sensor.
The resistance varies depending on the suction line temperatures. The thermistor
detects the temperature of the evaporator outlet to start the harvest timer or momentarily
stop the pump motor during the freeze cycle. No adjustment is required. If necessary,
check for resistance between thermistor leads, and visually check the thermistor
mounting, located on the suction line next to the evaporator outlet.
Temperature (°F) Temperature (°C)
Resistance (k
Ω
)
0
-18
14.401
10
-12
10.613
32
0
6.000
50
10
3.871
70
21
2.474
90
32
1.633
Check a thermistor for resistance by using the following procedure:
1) Disconnect the connector K1 on the board.
2) Remove the thermistor. See “V. 13. THERMISTOR”.
3) Immerse the thermistor sensor portion in a glass containing ice and water for 2 or 3
minutes.
Summary of Contents for KM-40B
Page 1: ...KM 40B KM 55B KM 80B SELF CONTAINED CRESCENT CUBER SERVICE MANUAL F120 1011 073117 ...
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a KM 40B Europe ...
Page 6: ...2 b KM 40B Singapore ...
Page 7: ...3 c KM 40B Australia New Zealand ...
Page 8: ...4 d KM 40B Philippines ...
Page 9: ...5 e KM 55B Europe ...
Page 10: ...6 f KM 55B Singapore ...
Page 11: ...7 g KM 55B Australia New Zealand ...
Page 12: ...8 h KM 55B Philippines ...
Page 13: ...9 i KM 80B Europe ...
Page 14: ...10 j KM 80B Singapore ...
Page 15: ...11 k KM 80B Australia New Zealand ...
Page 16: ...12 l KM 80B Philippines ...
Page 22: ...18 ...
Page 37: ...33 2 WIRING DIAGRAM a KM 40B Philippines b KM 40B Except Philippines KM 55B ...
Page 38: ...34 c KM 80B ...