16
H. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
• To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
• At startup, confirm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply and allow the icemaker to operate for a total of 10 minutes.
6) Turn off the power supply, then remove the front panel and the insulation panel.
7) Slide the cube guide to the right, then remove the rubber cap and sleeve covering the
overflow pipe. See Fig. 6. Unscrew the overflow pipe. After the water tank has drained,
reconnect the overflow pipe. Replace the rubber hose, overflow cap, and cube guide in
their correct positions.
NOTICE
! Make sure the O-ring is attached to the bottom of
the overflow pipe and be careful not to cross thread the overflow pipe.
8) Replace the insulation panel and the front panel in their correct positions.
9) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
10) Turn on the power supply to start the automatic icemaking process.
11) When the icemaker is running, hold an ice cube in
contact with the bulb. The icemaker should stop within
10 seconds. Adjustment may be needed, particularly at
higher altitude locations.
Fig. 6
Rubber Hose
Overflow Pipe
O-Ring
Cube Guide
Overflow Cap