14
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
Condensation
Drain Outlet
1/2" Female Pipe
Thread (FPT)
3/8" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal
ID Hard Pipe or
Equivalent
3/8" OD Hard
Tube
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Drain Valve
Shut-Off Valve
Minimum 3/8" Nominal ID Copper
Water Tubing or Equivalent
Icemaker Water Supply Inlet
1/2" FPT
Icemaker
Drain Outlet
3/4" FPT
Icemaker
Condensation
Drain Outlet
3/8" OD Hard
Tube
Ice
Storage
Bin
Icemaker
Vent Tube
Bin Drain Outlet
3/4" FPT
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
2-inch (5-cm) air gap
Floor Drain
Be sure there is sufficient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the
drain.
Fig. 5
Air-Cooled Models
Model Shown:
KM-1100MAJ50