57
6) Pour the cleaning solution into the Water Tank. Move the Control Switch to the
“SERVICE” position and the Service Switch to the “WASH” position. Close the Door.
7) After 30 minutes, move the Control Switch to the “OFF” position.
8) Same as step 4.
9) Move the Control Switch to the “ICE” position to fill the Water Tank with water.
10) After 3 minutes, move the Control Switch to the “SERVICE” position and the Service
Switch to the “WASH” position.
11) After 5 minutes, move the Control Switch to the “OFF” position.
12) Same as step 4.
13) Repeat steps 9 through 12 three more times to rinse thoroughly.
14) Disconnect the Overflow Pipe. Next, remove the Water Tank by removing the two
Thumbscrews and pulling the tank towards you slightly and pushing it down. Be
careful to avoid breakage when handling the parts. See Fig. 16.
15) Pull the Cube Guides (quantity varies depending on model) upward to remove them
from the Water Tank. They are snapped in place. See Fig. 17.
16) Same as step 1.
17) Wash the Bin Control Switch, Water Tank, Float Switch, Cube Guide and Overflow
Pipe by using a nylon scouring pad, brushes and the cleaning solution. In addition to
the removed parts, also wash the bin liner and Bracket (L) (R) with the solution.
18) Discard the cleaning solution and rinse the parts thoroughly with water.
[b] SANITIZING PROCEDURE - Following Cleaning Procedure
1) Dilute approximately 15 ml or 1 tbs of a 5.25% sodium hypochlorite solution (chlorine
bleach) with 3.8 lit. of warm water. Using a chlorine test strip or other method,
confirm that you have a concentration of about 200 ppm.
2) Soak the removed parts from step 17 above in a clean container containing the
sanitizing solution. After allowing the parts to soak for 10 minutes, wash them with
the solution. Also wash the bin liner, Bracket (L) (R) with the solution.
3) Discard the sanitizing solution and rinse the parts thoroughly with water.
4) Replace the removed parts in their correct positions in the reverse order of which