A. Specification and Performance Data Sheets
1. IM-500SAB
Specification Sheet
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
11.5 A (5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1000 (5.80)
830 (4.05)
WATER gal./24HR (gal./100 lbs.)
95 (23.0)
117 (24.0)
SHAPE OF ICE
Square Cube
ICE PRODUCTION PER CYCLE
7.2 lbs. (3.3 kg) 140pcs.
BIN CONTROL SYSTEM
Mechanical Bin Control
REFRIGERANT CHARGE
R404A, 1 lb. 10.5 oz. (750g)
Performance Data Sheet
70/21
489
222
467
212
444
201
80/27
472
214
438
199
418
190
90/32
467
212
414
188
392
178
lbs./day kg./day
100/38
465
211
409
185
372
169
70/21
80/27
90/32
watts
100/38
70/21
117
0.44
111
0.42
102
0.39
80/27
112
0.43
102
0.39
94
0.36
90/32
111
0.42
95
0.36
87
0.33
gal./day m
3
/day
100/38
101
0.38
93
0.35
79
0.30
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
209
14.7
233
16.4
257
18.1
80/27
227
16.0
264
18.6
284
20.0
90/32
233
16.4
290
20.4
312
22.0
PSIG kg/cm
2
G
100/38
235
16.5
295
20.8
333
23.4
70/21
47
3.3
49
3.5
52
3.7
80/27
49
3.4
52
3.7
55
3.9
90/32
49
3.5
55
3.9
58
4.1
PSIG kg/cm
2
G
100/38
50
3.5
56
3.9
60
4.2
4,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
1,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
19
23
26
891
1015
1120
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
830
880
943
868
945
1005
880
1000
1063
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
18
19
21
19
21
23
19
23
25
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
2.3
3.2
2.4
1.9
2.7
2.3
1.4
HARVEST CYCLE TIME
3.6
3.2
3.3
2.8
2.8
ENG.F-011.1.0205