15) Connect the leads (with three-way plug) located in the lower unit
wiring channel to the upper or middle unit receptacle, unplugged in
the above step 10). Secure the leads using the plastic clamp
provided. Place the plastic cover in position. See Fig. 10.
16) Replace the icemaker panels in their correct position.
Note: If stacking three icemakers, repeat the instructions 10) - 16) for
the upper unit. Remember, only ONE Bin Control is needed
regardless of configuration. The Bin Control extension leads
are pre-wired with the plug and will be found coiled in the X-
type wiring channel.
* Should the socket outlets in the installation site not be suitable for the
plug supplied with your product, the plug must be removed (cut off if
it is moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord,
it must be disposed of. There should be no attempt to reuse it.
Inserting such a plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used without a fuse cover
being fitted.
The correct replacement for the detachable fuse cover is identifiable
from the manufacturer’s reference number stamped on the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki
Parts/Service Centres.
Fuses should be rated at 13A and approved to BS 1362.
6. WATER SUPPLY AND DRAIN CONNECTIONS
(For the U.K. only, the connections must be in accordance with current
requirements of the Model Water Byelaws 1986 SI No. 1147)
* Only potable water should be used for the icemaker.
* Water supply pressure should be minimum 0.5 bar and maximum 8
bar. If the pressure exceeds 8 bar, use a proper pressure reducing
valve. Do NOT throttle back the supply tap.
* A plumbing permit and services of a licensed plumber may be required
in some areas.
5. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the national and local
electrical code requirements. To prevent possible severe
electrical shock to individuals or extensive damage to equipment,
install a proper earth wire to the icemaker. Remove the plug
from the mains socket before any maintenance, repairs or
cleaning is undertaken.
* This icemaker must have a separate power supply or receptacle of
220 - 240V.
* Stacked icemakers should each have a separate receptacle, but
they must all be connected in parallel to the same single phase
supply or circuit with sufficient ampacity. In addition and to avoid
nuisance tripping, individual circuit breakers for each machine should
not be used.
* The main control box fuse is rated at 5A and should only be replaced
by a qualified service engineer.
* Usually an electrical permit and services of a licensed electrician are
required.
* If the supply cord and the plug should need to be replaced, it should
only be done by a qualified service engineer.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected
to the terminal in the plug which is marked with the letter E or by the
symbol or coloured Green or Green-and-Yellow. The wire which
is coloured Blue must be connected to the terminal which is marked
with the letter N or coloured Black. The wire which is coloured
Brown must be connected to the terminal which is marked with the
letter L or coloured Red.
Fig. 10
Plastic Clamp
Lower Unit
Receptacle
Upper Unit
Plug
Wiring Channel
*Cooling Water Inlet
Water Inlet
Water Inlet
Drain Outlet (Upper Unit)
Elbow
Union
Middle Unit
Lower Unit
Upper Unit
*Cooling Water Outlet
(IM-720)
*Cooling Water Inlet
*Cooling Water Outlet
Water Inlet
Fig. 11
*Cooling Water Inlet
Water Inlet
Drain Outlet
(Icemaker dump)
Drain Outlet (Bin)
Drainage
*Cooling Water Outlet
* Water-cooled
model only
(IM-240)
Fig. 12
* Water-cooled
model only
Drain Outlet (Lower Unit)
Drainage
Drain Outlet (Bin)
Tee
Storage Bin
*Cooling Water Inlet
*Cooling Water Outlet
Drain Outlet (Middle Unit)