57
7. WATER REGULATING VALVE - WATER-COOLED MODEL ONLY
[a] VALVE BODY
1) Unplug the icemaker or disconnect the power source.
2) Close the water supply tap.
3) Remove the front panel and right side panel.
4) Disconnect the flare connections of the water regulating valve.
5) Remove the valve from the bracket.
6) Install a new water regulating valve.
7) Connect the flare connections.
8) Open the water supply tap.
9) Check for water leaks.
10) Replace the panels in their correct positions.
11) Plug in the icemaker or connect the power source.
[b] WHOLE VALVE
IMPORTANT
Always install a new drier every time the sealed refrigeration system is
opened. Do not replace the drier until after all other repair or replacement
has been made.
1 Unplug the icemaker or disconnect the power source.
2) Close the water supply tap.
3) Remove the front, top and right side panels.
4) Recover the refrigerant and store it in a proper container, if required by an applicable
law (See “1. [b] REFRIGERANT RECOVERY”).
5) Cut off the copper tube near the capillary tube solder connection, using a pipe cutter.
Summary of Contents for IM-240ANE
Page 4: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a IM 240DNE Air cooled ...
Page 5: ...2 b IM 240DNE C Air cooled ...
Page 6: ...3 c IM 240DWNE Water cooled ...
Page 7: ...4 d IM 240DWNE C Water cooled ...
Page 8: ...5 e IM 240DWNE R452 Water cooled ...
Page 9: ...6 f IM 240ANE Air cooled ...
Page 10: ...7 g IM 240AWNE Water cooled ...
Page 11: ...8 h IM 240DSNE Remote Air cooled ...
Page 12: ...9 j URC 240C E 4 Condenser Unit ...
Page 20: ...17 a CONTROLLER BOARD LAYOUT Main Board Sub Board Combination ...
Page 37: ...34 2 WIRING DIAGRAM a IM 240DNE C XNE C IM 240DWNE C R452 XWNE C R452 IM 240ANE AWNE ...
Page 38: ...35 b IM 240DSNE XSNE URC 240C E 4 ...
Page 69: ...66 Fig 16 Controller Board Board Support Control Box Cover Screw ...