19
Holder
Screw
Thermistor
Evaporator
Component
1. Thermistor
(on evaporator)
2. Bin Control Switch
Procedure
CAUTION
Thermistor sensor part is fragile,
glass sealed. Handle with care.
* Disconnect the connector CN13 on
the board.
* R e m o v e t h e s c r e w a n d t h e
thermistor holder on the evaporator.
* Immerse the sensor part in a glass
containing ice and water for 5
minutes.
* Check the resistance between CN13
connector pins.
* Replace the thermistor in its correct
position.
* Connect CN13.
Manually set the micro switch in the
TRIP and RESET positions, and
check the period.
Normal
5 -7 kilohms
Approx.
TRIP(Closed) 10 sec.
RESET(Open) 80 sec.
[c] BEFORE CHECKING CONTROLLER BOARD
Check the power source voltage and the components as shown in the table below.