43
Suction Pressure and Evaporator Temp.
50/60Hz
Model
Ambient
Temp.
(°C)
10 21 32 38
Water
Temp.
(°C)
10 15 21 32
IM-240_NE
Suction Pressure Peak (bar)
3.0
3.5
4.0
5.0
Evaporator Inlet Temp. (°C)
-20
-19
-18
-17
IM-240_NE-21
Suction Pressure Peak (bar)
3.0
3.5
4.0
5.0
Evaporator Inlet Temp. (°C)
-13
-11
-10
-9
IM-240_NE-32
Suction Pressure Peak (bar)
3.0
3.5
4.0
5.0
Evaporator Inlet Temp. (°C)
-23
-22
-21
-20
Note: The above data are only for reference in servicing. Actual readings may be slightly different for
each product.
Suction Pressure = Peak readings in freezing cycle
Evaporator Inlet Temp. = 5 minutes before completion of freezing cycle