63
2. LOW ICE PRODUCTION
PROBLEM POSSIBLE
CAUSE
REMEDY
1. Gas leaks.
1. See 1 - [5] - a).
2. Refrigerant line
clogged.
2. Replace the clogged
component.
a) Refrigerant Line
3. Overcharged.
3. Recharge.
1. Dirty Air Filter or
Condenser.
1. Clean.
2. Ambient or condenser
water temperature
too warm.
2. Check for recommended
temperature.
3. Condenser water
pressure too low or
off.
3. Check and get recommended
pressure.
4. Fan rotating too slow.
4. See 3 - [1] - a).
b) High-side
Pressure Too
High
5. Water Regulating
Valve clogged.
5. Clean.
c) Expansion Valve
(not adjustable)
1. Low-side pressure
exceeding the limit.
1. Replace.
[1] Low ice
production.
d) Evaporator
1. Evaporator pipe
crushed.
1. Replace.
3. OTHERS
PROBLEM
POSSIBLE CAUSE
REMEDY
1. Bearing worn out.
1. Replace.
2. Fan blade deformed.
2. Replace fan blade.
a) Fan Motor
(Condenser Unit)
3. Fan blade does not
move freely.
3. Replace.
1. Bearings worn out, or
cylinder valve broken.
1. Replace.
b) Compressor
2. Mounting pad out of
position.
2. Reinstall.
c) Refrigerant Lines
1. Rub or touch lines or
other surfaces.
1. Replace.
d) Gear Motor (Ice
Making)
1. Bearing or Gear
wear/damage.
1. Replace.
1. Low-side pressure too
low.
1. See if Expansion Valve Bulb is
mounted properly, and
replace the valve if necessary.
e) Evaporator
2. Scale on inside wall of
Freezing Cylinder.
2. Remove Auger. Use a solution
of lime removing cleaner to
clean periodically. If water is
found to surpass the following
levels, install a conditioner.
Hardness 50 ppm
Silica 30 ppm
f) Heater
1. Broken.
1. Replace.
[1] Abnormal noise
g) CPR (Condenser
Unit)
1. Internal leaks.
1. Replace.
Summary of Contents for FM-300AFE-HC
Page 7: ...3 2 DIMENSIONS CONNECTIONS a FM 481AGE HC FM 481AGE HCN ...
Page 8: ...4 b FM 300AFE HC FM 300AFE HCN ...
Page 9: ...5 3 SPECIFICATIONS a FM 481AGE HC ...
Page 10: ...6 b FM 481AGE HCN ...
Page 11: ...7 c FM 300AFE HC ...
Page 12: ...8 d FM 300AFE HCN ...
Page 14: ...10 Drier Ice Chute Pressure Switch ...
Page 23: ...19 b FM 300AFE HC FM 300AFE HCN Pressure Switch Cut out 22 6 1 5 0 bar Cut in 15 7 1 5 bar ...
Page 24: ...20 2 WIRING DIAGRAM a WIRING DIAGRAM FM 481AGE HC FM 481AGE HCN ...
Page 25: ...21 FM 300AFE HC FM 300AFE HCN ...
Page 26: ...22 b CONTROL BOX LAYOUT FM 481AGE HC FM 481AGE HCN ...
Page 27: ...23 FM 300AFE HC FM 300AFE HCN ...
Page 35: ...31 FM 300AFE HC FM 300AFE HCN ...
Page 36: ...32 ...
Page 37: ...33 c SEQUENCE FM 481AGE HC FM 481AGE HCN 1 Startup Water Supply ...
Page 39: ...35 FM 481AGE HC FM 481AGE HCN 3 Startup Ice production starts ...
Page 40: ...36 FM 481AGE HC FM 481AGE HCN 4 Normal Operation Bin Control ...
Page 41: ...37 FM 481AGE HC FM 481AGE HCN 5 Shutdown Compressor stops 5 min ...
Page 42: ...38 FM 481AGE HC FM 481AGE HCN 6 Shutdown Drain ...
Page 43: ...39 FM 300AFE HC FM 300AFE HCN 1 Startup Water Supply ...
Page 45: ...41 FM 300AFE HC FM 300AFE HCN 3 Startup Ice production starts ...
Page 46: ...42 FM 300AFE HC FM 300AFE HCN 4 Normal Operation Bin Control ...
Page 47: ...43 FM 300AFE HC FM 300AFE HCN 5 Shutdown Compressor stops 5 min ...
Page 48: ...44 FM 300AFE HC FM 300AFE HCN 6 Shutdown Drain ...