32
F-800MWF
APPROXIMATE
Ambient
Water Temp. (°F)
ICE PRODUCTION
Temp. (°F)
PER 24 HR.
70
720
(327)
695
(314)
680
(309)
80
670
(304)
660
(299)
650
(294)
90
640
(290)
625
(284)
620
(280)
lbs./day ( kg/day)
100
605
(276)
595
(271)
555
(252)
APPROXIMATE ELECTRIC
70
1090
--
1100
--
1120
--
CONSUMPTION
80
1090
--
1100
--
1120
--
90
1090
--
1100
--
1120
--
watts
100
1090
--
1100
--
1120
--
APPROXIMATE WATER
70
405
(1.84)
569
(2.59)
944
(4.29)
CONSUMPTION PER 24 HR.
80
422
(1.92)
590
(2.68)
984
(4.47)
(TOTAL)
90
436
(1.98)
614
(2.79)
1027
(4.67)
gal. / day (l/day)
100
450
(2.05)
636
(2.89)
1126
(5.12)
EVAPORATOR OUTLET TEMP.
70
21
(-6)
22
(-6)
21
(-6)
°F (°C)
80
22
(-6)
22
(-6)
22
(-6)
90
21
(-6)
22
(-6)
22
(-6)
100
23
(-5)
23
(-5)
22
(-5)
HEAD PRESSURE
70
265
(18.6)
267
(18.8)
266
(18.7)
80
267
(18.8)
266
(18.7)
265
(18.7)
90
266
(18.7)
266
(18.7)
265
(18.7)
PSIG (kg/cm²G)
100
267
(18.8)
269
(18.9)
268
(18.8)
SUCTION PRESSURE
70
37
(2.6)
37
(2.6)
37
(2.6)
PSIG (kg/cm²G)
80
38
(2.6)
37
(2.6)
38
(2.6)
90
38
(2.6)
38
(2.6)
38
(2.7)
100
39
(2.7)
39
(2.7)
39
(2.7)
WATER FLOW FOR CONDENSER
44 gal/h (AT 90°F /WT 70°F)
PRESSURE DROP OF COOLING WATER LINE
Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER
6270 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR
1290 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
We reserve the right to make changes in specifications and design without prior notice.
Summary of Contents for F-800MAF
Page 9: ...9 2 CONDENSER UNIT URC 6F ...
Page 15: ...15 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAF C ...
Page 16: ...16 F 800MWF C ...
Page 17: ...17 2 WIRING DIAGRAMS F 800MAF C F 800MWF C ...
Page 19: ...19 b When Reservoir has been filled Gear Motor starts immediately ...
Page 20: ...20 c Compressor starts about 60 sec after Gear Motor starts ...
Page 21: ...21 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously ...
Page 22: ...22 e Low Water Except Water cooled Model ...
Page 25: ...25 h When Flush Timer operates for 15 min every 12 hours ...