55
[Water-cooled Models]
1) Turn off the power supply and wait for 3 minutes.
2) Turn on the power supply and wait for 20 seconds.
3) Close the Water Supply Line Shut-off Valve.
4) Open the Drain Valve and quickly blow the water supply line from the Drain Valve to drain
water in the Condenser.
5) Follow the above steps 3) through 11) in [Air-cooled and Remote Air-cooled Models].
Summary of Contents for F-800MAF
Page 9: ...9 2 CONDENSER UNIT URC 6F ...
Page 15: ...15 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAF C ...
Page 16: ...16 F 800MWF C ...
Page 17: ...17 2 WIRING DIAGRAMS F 800MAF C F 800MWF C ...
Page 19: ...19 b When Reservoir has been filled Gear Motor starts immediately ...
Page 20: ...20 c Compressor starts about 60 sec after Gear Motor starts ...
Page 21: ...21 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously ...
Page 22: ...22 e Low Water Except Water cooled Model ...
Page 25: ...25 h When Flush Timer operates for 15 min every 12 hours ...