22
© 2 0 0 5 D i r e c t e d E l e c t r o n i c s — a l l r i g h t s r e s e r v e d
V
Voollttaaggee M
Mood
dee//T
Taacch
hoom
meetteerr M
Mood
dee - Default is voltage mode
which is monitored through the 12V inputs to the control
module. When in voltage mode the unit will monitor the voltage
of the vehicle when remote started, to determine if the vehicle is
running (battery voltage will rise after the engine starts).
To program tachometer mode:
1. Start the engine.
2. Press and hold the program button on the control module
within 25 seconds of starting the engine.
3. The parking lights will turn on and stay on until the button is
released. The unit has now learned the vehicle tachometer signal
and is programmed to the tachometer mode.
note:
If the tachometer signal to the unit is lost after
learning the tachometer, the unit will make 2 start
attempts in Tachometer Mode before automatically
returning to the Voltage Mode.
note:
If the lights do not turn on the unit has not
learned the vehicle Tachometer signal and will
remain in voltage mode. Check the Violet/White
(H1/2) wire for proper connection.
note:
If only voltage mode is desired for remote
start, the Violet/White wire (H1/2) does not need
to be connected.