background image

12/3/2019 | MAN1131-06-EN

Indianapolis, USA  |  Cork, Ireland  |  Calgary, Canada  |  Bangalore, India  |  Oakleigh, Australia  |  Tianjin, China  |  Esteio, Brazil

Please visit our website for a complete listing and to learn more about certified Horner Automation products.
This document is the property of Horner Automation Group, and is subject to change. 

 

1  TECHNICAL SPECIFICATIONS

1.6 Control & Logic

Control Language 
Support

Advanced ladder 
logic Full IEC 61131-3 
languages

Logic Program Size

256kB

Non-Retentive Memory

128kB

Internal Storage 
Memory 

16Mb

Total Program Memory

2.5Mb

Logic Scan Rate

1.2ms/kB 

%I (Digital Inputs)

1024

%Q (Digital Outputs)

1024

%AI (Analog Inputs)

256

%AQ (Analog Outputs)

256

%M (Retentive Bits)

1024

%T (Temporary Bits)

1024

%R (Retentive Registers)

5000

%D (Display bits)

250

%K (Function Keys)

10

%S (System Bit)

16

%SR (System Register)

255

1.2 Connectivity

Serial Ports

1 x RS232, 1 x RS485

485 Terminations

On-board, software 
controlled

Mini USB 

Programming Only

CAN Hardware

Non-isolated

CAN Port Connector

RJ45 (red)

CAN Port Speeds 
Support

125kB, 250kB, 
500kB, 1MB/sec.

CAN Port Termination

On-board, software 
controlled

CAN Protocols

CsCAN

Removable Memory In

microSD, SDHC, SDXC 
IN FAT32 format, 
support for 32GB max. 
Application Updates, 
Datalogging, more.

1.5 User Interface

Display

2.2” Monochrome LCD

Resolution

128 x 64 pixels

Backlight

LED

Backlight Lifetime

50,000 hrs

Backlight Control

Software  
controlled (ON/OFF)

User-Programmable 
Screens/Pages

250

No. of Objects/Screens

15

Screen Memory

256kB

Keypad

Membrane type switches 
w/metal dome

Tactile Feedback

Yes

Number of Keys

4 Soft keys + 16  
numeric/function keys

X OCS MODEL: HE-X2

MODEL A BUILT-IN I/O:     12 DIGITAL INPUTS, 12 DIGITAL OUTPUTS, 4 ANALOG INPUTS, 2 ANALOG OUTPUTS
MODEL R BUILT-IN I/O:     12 DIGITAL INPUTS, 6 RELAY OUTPUTS, 2 PWM OUTPUTS, 4 ANALOG INPUTS, 2 ANALOG OUTPUTS

1.1 General

Primary Pwr. Range

24VDC +/- 20%

Typical power-back-
light 100%

64mA @ 24V (1.53W)

Power Backlight Off

15mA @ 24V (0.36W)

Inrush Current

30A for  

<

 1ms

Real Time Clock

Battery backed;
lithium coin cell CR2450

Clock Accuracy

+/- 90 Secs/Month

Relative Humidity

5 to 95%  Non-condensing

Operating Temp.

-10°C to +60°C

Storage Temp.

-20°C to +70°C

Weight

0.75 lb/ 340g 

Mounting Clips

4 composite type

Housing Material

Polycarbonate, UL rated

Panel Seal

Silicone rubber

Packaging

100% recyclable  
paper fiber materials

Included in Box

Controller,  
3 x I/0 connectors,  
4 x mounting clips,  
1 x power connector, 
Quick Reference Guide

1.3 I/O Connections

Terminal Type

Removable 3.5mm 
color-coded

I/O Options

O Remote- 
SmartMod, SmartRail, 
SmartBlock, SmartStix

1.4 Testing 

Shock

IEC 60068-2-27

Vibration

IEC 60068-2-6

UL Environmental 
Ratings

Type 1, 4, 4X, 12, 12k & 
13 for indoor use

Certifications  
(UL/CE)

USA:    h

ttps://hornerauto-

mation.com/certifications/ 

Europe:  

http://www.

horner-apg.com/en/support/
certification.aspx

1.7 Inputs/Outputs Model Overview

MODEL R

MODEL A

DC In

12

12

DC Out

2

12

Sinking

Yes

No

Sourcing

Yes

Yes

Relays

6

HS In

4

4

HS Out

2

2

mA In

4

4

mA Out

2

2

There are four high-speed inputs (I1-I4) of the total DC 
Inputs.  
There are two high-speed outputs (Q1-Q2) of the total DC 
outputs.

Model A DC Outputs are Sourcing. 

Model R DC outputs are sinking with integral pull up resis-
tors.  Model R also supports sourcing. 

page 1 of 6

technical specifications continued on next page...

Summary of Contents for X OCS Series

Page 1: ...edback Yes Number of Keys 4 Soft keys 16 numeric function keys X OCS MODEL HE X2 MODEL A BUILT IN I O 12 DIGITAL INPUTS 12 DIGITAL OUTPUTS 4 ANALOG INPUTS 2 ANALOG OUTPUTS MODEL R BUILT IN I O 12 DIGITAL INPUTS 6 RELAY OUTPUTS 2 PWM OUTPUTS 4 ANALOG INPUTS 2 ANALOG OUTPUTS 1 1 General Primary Pwr Range 24VDC 20 Typical power back light 100 64mA 24V 1 53W Power Backlight Off 15mA 24V 0 36W Inrush C...

Page 2: ...ncludes information on Built In I O Common S SR Registers Resource Limits 1 9 Model R Digital DC Outputs Sinking Sourcing Outputs per Module 2 PWM or HSC Commons per Module 1 Type Sinking Absolute Max Voltage 28VDC Output Protec tion Short circuit Max Output per Point Sinking 0 5A Max Output per Point Sourcing 2 4mA 24V Max Voltage Drop at Rated Current 0 25VDC Max Outrush 650mA Min Max OFF to ON ...

Page 3: ... wiring used in order for the correct input states to be registered Removing and Inserting Connectors Use a small screwdriver to gently pry up the connector Gently press on connector to snap into place Wiring Details Solid Stranded Wire 12 24 awg 2 5 0 2mm Strip Length 0 28 7mm Torque Rating 4 5 7 in lbs 0 50 0 78 Nm 3 2 Relay Life WARNING Exposure to some chemicals may degrade the sealing proper ...

Page 4: ... Outputs Q1 C Load LOAD SINKING Q1 Q2 V C Model R Sourcing Outputs LOAD SOURCING Q1 Q2 V C Q1 10kΩ V C Load Sourcing 0 5A sourcing 24V L N L N L N L N L N L N J1 Wiring Model R Relay and Digital Out POSITION PIN DIGITAL MODEL 1 R1 Relay 1 N O 2 C1 Relay 1 C 3 R2 Relay 2 N O 4 C2 Relay 2 C 5 R3 Relay 3 N O 6 C3 Relay 3 C 7 R4 Relay 4 N O 8 C4 Relay 4 C 9 R5 Relay 5 N O 10 C5 Relay 5 C 11 R6 Relay 6...

Page 5: ...CAN network should be terminated 4 COMMUNICATIONS 4 1 CAN Communications CAN Pin Assignments PIN SIGNAL 8 No Connection 7 Ground 6 Shield 5 No Connection 4 No Connection 3 Ground 2 CAN Data Low 1 CAN Data High CAN Modular jack 8posn RJ45 POSITION PIN DIGITAL MODEL 1 AI1 Analog Input 1 2 AI2 Analog Input 2 3 AI3 Analog Input 3 4 AI4 Analog Input 4 5 C Common 6 C Common 7 AQ1 Analog Output 1 8 AQ2 A...

Page 6: ...ended to fuse the voltage measurement inputs Be sure to locate fuses as close to the source as possible 5 Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards 6 In the event of repeated failure do NOT replace the fuse again as repeated failure indicates a defective condition that will NOT clear by replacing the fuse 7 Only qualified electrical per...

Reviews: