Horizont 1011008 Instruction Manual Download Page 2

Electric  Fences shall  be  installed  and 

operated  so  that  they 

cause no electrical hazard to persons, animals or their sur-
roundings. 

Safe application is provided if the following hints are respect-
ed:   

Not as much Joules as possible but as much as necessary. 
Short fences up to 10 km without weedload can be operated 
with 0,2 to 0,5 Joule pulse energy, medium fences (approx 20 
km) also with light weedload with max 2 or 3 Joules. 

In cases where unsupervised children can be available  (espe-
cially in and around residential areas) also at electrical animal 
fences with alternating polarity – where the fence wires are al-
ternating connected with the fence and earth terminal - the low-
er output terminal – if available -should be used or low energy 
energizers or low output terminals of the energizers (1 joule).

WARNING:

  Do  not  touch  the  fence  with  the  head,  mouth, 

neck or torso. 

•  Avoid any electric animal fence with alternating polar-

ity  where  persons  can  get  between  fence  wires  with 
different  polarity.  If  at  all  use  energizers  with  lower 
energy  e.g  with  1  Joule  limitation  -  also  with  a  non-
electrified earthed wire !

•  Enable persons to pass through public pathways by means 

of  insulated  gates,  gatehandles  and  insulated  styles.  Do 
not climb over, through or under a multi·wire electric fence. 
Use a gate or a specially designed crossing point. At any 
crossing  at  any  crossway  and  along  public  pathways  all 
electrified  wires must  be  identified  by warning signs in a 
distance of at least 100 m.

•  Keep a distance of at least 2,5 m with the electric fence to 

all metallic parts i.e. to waterpipes and troughs especially 
if persons can be in the vicinity.

•  If there is a danger of overflooding the energizer must be 

turned off.

Pay attention to Annex BB1. 
The energizer has a pulse interval of 1 to 2.0 seconds. If the 
interval is less than 1 second the energizer is to be repaired, 
if the interval is more than 2.0 seconds the fence is not longer 
safe in function and must be repaired, too.

 

 This device fulfils the requirements contained in EU Di-

rective 2014/30/EU “Electromagnetic compatibility”, 2011/65/
EU  (RoHS)  +  2012/19/EU  (WEEE)  and  with  the  European 
Safety  Standard  EN  60335-2-76  (Electric  fence  energizer) 
the EC-directive 2001/95/EC (General product safety).

Help to avoid any misuse of the energizer by:
•  Observing the printing 
•  Secure the energizer against unallowed access (e.g. an-

titheft or antichildren equipment) if the location make this 
necessary

SAFETY HINTS ELECTRIC ANIMAL FENCE     

General hints for the installation and operation

Special  applications  of 

electric  fences

  in 

zoos

  and 

deer 

fences:

 The mounting of such installations may only be car-

ried out by trained specialists, a mechanical barrier must be 
provided which separates the electric fence from visitors.

Service: 

If the connecting cable of this device is damaged, 

the manufacturer, his after-sales service or a similarly quali-
fied person must replace it in order to avoid hazard. Services 
and repairs only by authorized experts! Only by the manufac-
turer commanded replacement parts must be used.

PART 2:
PRINCIPLES  AND  LIMITATIONS  OF  ELECTRIC 
FENCING FOR ANIMALS

An  electric  fence  consists  of  an  energizer  and  a  connected 
fence  where  the  energizer  feeds  electric  impulses  into  the 
fence. The  electric  animal  fence  represents  a  “psychological 
barrier”  for  the  animals;  it  keeps  animals  inside  or  outside  a 
certain area ,it can also be used to train a certain behaviour 
(e.g. cow  trainer in the  stable). The  electric  security  fence is 
used for security purposes that comprise an electric fence and 
a physical barrier electrically isolated from the electric fence.
No  electric  or  mechanical  fence  can  guarantee  a  100%  ef-
fective solution in protecting or containing your animals. The 
effectiveness of an electric fence may vary upon the unique 
local conditions within which the fence is installed. A suitable 
combination of products together with competent installation 
will ensure  the best results. On occasion a determined ani-
mal may overcome the most rigid of mechanical fences or the 
most  comprehensive electric  fence  system.  For  this  reason 
the seller gives no assurance that the fence system is 100% 
safe against outbreak. A well installed electric fence can of-
fer a high level of security when compared to a mechanical 
fence, as the psychological barrier an electric shock can rep-
resent will deter the animal from finding a way to circumnavi-
gate the fence. Electric fences will also offer far greater level 
of flexibility.

ANNEX BB.1
REQUIREMENTS FOR  ELECTRIC ANIMAL FENCES 
Electric  animal  fences

  and  their  ancillary  equipment  shall 

be installed, operated and  maintained in a manner that mini-
mises danger to persons, animals or their surroundings.

Electric animal fence constructions

 that are likely to lead 

to the entanglement of animals or persons shall be avoided.

An 

electric  animal  fence

  shall  not  be  supplied  from  two 

separate 

energisers

 or from independent 

fence circuits

 of 

the same 

energiser

CAUTION:

  Touching  electrified  fences,  especially  with  the 

head, neck or upper body, should be avoided. Do not climb 
over the fence, through the fence or under the fence. To pass 
through the fence, use a gate or other crossing facility.

For any two separate 

electric animal fences

, each supplied 

from a separate 

energiser

 independently timed, the distance 

between the wires of the two electric animal fences shall be at 
least 2,5 m. If this gap is to be closed, this shall be effected by 
means of electrically non conductive material or an isolated 
metal barrier.

Barbed  wire  or  razor  wire  shall not  be  electrified  by an 

en-

ergiser

A non-electrified fence incorporating barbed wire or razor wire 
may be used to support one or  more off-set electrified wires 

Summary of Contents for 1011008

Page 1: ...PIKO A100 Type 1011008 PIKO A100 0 7 J 0 45 J 10 000 50 m 12 km 10 km INSTRUCTION MANUAL Electric Fencer INSTRUKCJA OBS UGI Elektryzator Signal d o o Zbilje 4 h 1215 Medvode Slovenia 1 km 3 km...

Page 2: ...Service If the connecting cable of this device is damaged the manufacturer his after sales service or a similarly quali fied person must replace it in order to avoid hazard Services and repairs only...

Page 3: ...pply mains equivalent to that provided by the energizer NOTE 1Ancillary equipment that complies with the require ments relating to isolation between the fence circuit and the supply mains in Clauses 1...

Page 4: ...w a ciwemu zastosowaniu elektryzatora mo na zapobiec poprzez Stosowanie si do wskaz wek w opisach na urz dzeniach np nie pod cza do sieci elektrycznej Zabezpieczenie elektryzatora przed dost pem os b...

Page 5: ...og by mniejsze ani eli przedstawione w tabeli BB 1 T o z obu stron tabliczki ostrzegawczej powinno by w kolo rze tym Napisy i symbole na tabliczce w kolorze czarnym powinny by symbolem wg rysunku BB1...

Page 6: ...1 10 0 2 0 5 20 2 3 1 1 100 2 5 BB1 1 1 5 1 2 2014 30 UE 2011 65 UE RoHS EN 60335 2 76 2001 95 WE 2 100 100...

Page 7: ...BB 1 1000 3 1000 i 33000 4 33000 8 3 2 1000 15 1000 100 x 200 BB 1 BB1 BB 1 2 5 6 10...

Page 8: ...25 1 14 16 29 EN 60335 2 76 IPX4 3 BB2 CC EN 60335 2 76 SECURA SECURITY...

Page 9: ...Total weight 0 7kg...

Page 10: ...se of long fences and dry conditions use an additional ground wire 2a with intermediate rods 2b see Fig 2 OPERATION AND CONTROL SEE FIG 3 12V PIKO A100 INDICATION 3B The controller gives pulse into th...

Page 11: ...odu uziemiaj cego 2a z pr tem OBS UGA I STEROWANIE PATRZ RYS 3 12V PIKO A100 PATRZ RYS 3 Urz dzenie pod czy do akumulatora za pomoc zacisk w Elektryzator przekazuje impuls do ogrodzenia OSTRZE ENIE Ni...

Page 12: ...PIKO A100 page 6 8 1 1a 1 2a 3 12 PIKO A100 3B a 12...

Reviews: