Horizon Signal SQ2 User Manual Download Page 10

WI-0055: SQ2 User Manual 

Version 1.0 

10

Horizon Signal 

SQ2 User Manual 

Assigning Controller Identities  

Before a program can be entered, all of the controllers in the system must be communicating. To accomplish this, each 
controller is given an identity. Additionally, when using wireless communication, each radio must be assigned a 
“Master” or “Remote” designation as well as an operating channel and baud rate. Cable can also be used to link the 
signals together. 

Enhanced 4.0.41 

New System? 

Connection        Radio 
Amount of 

Controllers 
Controller 

No 

 

1.  To begin, power on the Controller  with the PTS Programmer plugged in. You will be    

presented with the initial startup screen which displays the current software version 
number. 

 

2.    You will then be presented with the “New System” screen. By answering “No,” no   

changes are made to the controller’s identity. If you would like to make changes, use the 
arrow buttons to navigate the menu, and the plus/minus buttons to change the values. 

       Connection:  

 

Communication method. Choose from Radio,    

 

 

 

 

Cable, or Quartz (no communication). 

       Amount of Controllers: 

Total number of controllers in the signal system 

       Controller:   

 

Identity of this specific controller 

3.    Repeat this process on each controller in your system. Remember that each controller    

must have a different “Controller” Number, but the same total “Amount of Controllers” 
and “Connection” type. These settings only have to be configured once, unless you are 
changing the number of controllers in your system. 

Configuring the Radio  

PTS systems using radio communication require one Master radio which can relay program information to all other 
Remote radios in the system. There are 14 channels that can be used for communication. To configure a radio press 
the “M” menu button then scroll down and select “Configure Radio” from the main menu. 

1.  Use the Arrow buttons to select the Radio Type. Each system can only have one 

Master; All others must be set to Remote. 

2.  Set the Channel. All signals (Master and all Remotes) must be on the same channel. 

3.  Set the Baud rate. For Enhanced Mode (Multi-Signal 2.0 controllers), the baud rate 

should be 57600. For Compatibility Mode (using Multi-Signal 1.0 or a mix of 1.0 and 
2.0 controllers), the Baud rate must be set to 19200. 

4.  On the DataLink SRM6230 Radio, press the “Reset/Config” button. The LED labeled 

“M2” will illuminate. 

5.  On the PTS Programmer, change “Read” to “Send” using the Plus (+)  button. To 

apply the new radio configuration press the green “E” button repeatedly at a mod-
erate rate of speed until the “M2” & “M1” LEDs both go out. Next the “M2” LED 
will flicker and go back out while the “M1” LED will come back on and stay on. 

Configure Radio 

Read: - - -  

Channel 

11 

Baudrate 

57600 

Read 

Note: The PTS Programmer can read the configuration settings of a radio by following these same steps using the “Read” function. 
The radio settings will display at the top of the PTS Programmer beside “Read”. After reading radio settings unplug the PTS Pro-
grammer and cycle controller’s power. 

Radio Type         Remote 

Summary of Contents for SQ2

Page 1: ...WI 0055 SQ2 User Manual Version 1 0 1 Horizon Signal SQ2 User Manual User Manual...

Page 2: ...rtable traffic signal system Personnel involved in the use and operation of equipment shall be careful competent and trained in the safe operation of the equipment Warning information should be emphas...

Page 3: ...tions or would like additional assistance please feel free to contact us at the information below Horizon Signal Technologies 5 Corporate Blvd Reading PA 19608 Phone 800 852 8796 www horizonsignal com...

Page 4: ...Programmer 11 The Home Screen 11 Assigning Controller Identities 12 Configuring Radios 12 Main Menu 13 Basic Programming 13 Special Programming 15 Edit a Program 18 Download Upload Delete 18 System Op...

Page 5: ...WI 0055 SQ2 User Manual Version 1 0 5 Horizon Signal SQ2 User Manual...

Page 6: ...floor 3 Use handles to remove cart from trailer 4 Position SQ2 cart as necessary 5 Install optional outriggers as needed 6 Install optional solar panel as necessary 7 Raise cart to the operating posi...

Page 7: ...WI 0055 SQ2 User Manual Version 1 0 7 Horizon Signal SQ2 User Manual...

Page 8: ...roller installed To activate Enhanced Mode power on the controller with the Operation Selector switch in the upward position 2 Compatibility Operation Allows MS 2 0 Controllers to work in conjunction...

Page 9: ...menus Move Cursor The Home Screen The home screen is where the user can view current system status as well as monitor real time operation of the entire signal system PTS Programmer PC or RMS cable plu...

Page 10: ...o be configured once unless you are changing the number of controllers in your system Configuring the Radio PTS systems using radio communication require one Master radio which can relay program infor...

Page 11: ...ime and will be undetectable by motorists The PTS Programmer has several program templates for you to choose from These simple templates represent the most common types of work zones To pick the corre...

Page 12: ...ime An extra sensor must use the Red Clearance Extension circuit and must have Red Extens enabled in the PTS Programmer s System Options 4 Set the green time for Phase 2 C2 carts 3 4 These values can...

Page 13: ...n the given phase 2 Carts 1 2 Yellow Yellow time for the given phase Traffic Gap Amount of time between vehicles that the controller will hold a detection Delay The amount of time vehicle detection is...

Page 14: ...ty are limited to their minimum or base green times Unlock If set to Yes the vehicle detection can drop out before a green is served i e right turns Must use true presence detection Red Extens Set a m...

Page 15: ...ng mode in the event of a radio communication interruption 10 Give your program a name using the Arrow buttons to move the cursor and the Plus and Minus buttons to change characters Choose the Save op...

Page 16: ...he Main Menu allows you to load a program from the PTS Programmer s memory to the PTS controller and activate it Your PTS system must have the appropriate number of controllers for the program you wis...

Page 17: ...Substitution setting selected during programming Lamps Off Instead of a green indication lamps go dark during green intervals When the system is running in Quartz Substitution mode extended green tim...

Page 18: ...al is Enabled in the System Options Flash Signals will operate in the Flash mode selected in the System Options menu Red Flash Red Flash Yellow or Lamps Off Special programs allow for override of this...

Page 19: ...Mode for systems with exclusively MS 2 0 controllers 4 To use MS 1 0 Micro Terminal MS 1 0 Micro Terminals may be used on MS 2 0 controllers operating in Compatibility Mode There is no need to change...

Page 20: ...WI 0055 SQ2 User Manual Version 1 0 20 Horizon Signal SQ2 User Manual...

Page 21: ...WI 0055 SQ2 User Manual Version 1 0 21 Horizon Signal SQ2 User Manual...

Page 22: ...WI 0055 SQ2 User Manual Version 1 0 22 Horizon Signal SQ2 User Manual SQ2 Deployed Dimensions...

Page 23: ...WI 0055 SQ2 User Manual Version 1 0 23 Horizon Signal SQ2 User Manual SQ2 Stowed Dimensions 63 70 63 13 20 02 28...

Page 24: ...WI 0055 SQ2 User Manual Version 1 0 24 Horizon Signal SQ2 User Manual SQ2 Circuit Board Diagram Pilot car Remote Sensor...

Page 25: ...WI 0055 SQ2 User Manual Version 1 0 25 Horizon Signal SQ2 User Manual...

Page 26: ...l Version 1 0 26 Horizon Signal SQ2 User Manual Terminal Block Pin Out All connections to the Multi Signal 2 0 controller are made via the Terminal Block located inside the SQ2 console box See the dia...

Page 27: ...WI 0055 SQ2 User Manual Version 1 0 27 Horizon Signal SQ2 User Manual...

Page 28: ...ource such as a generator The battery charger can be connected to a 110v power source by using the power adapter located on the back of the battery box See the chart below for battery charge levels If...

Page 29: ...aintenance The buyer expressly agrees that the buyer s sole remedy and the manufacturer s sole responsibility in respect to a warranty claim is exclusively limited to repair or replacement at the manu...

Page 30: ...quality versatile portable traffic signal systems that will stand the test of time We are dedicated to meeting the ever changing needs of today s traffic control industry and those of our customers P...