8. Trouble Shooting 

 

 

1.  Make sure the dry Hydrogen gas to be used must be 

99.995% purity. 

2.  The tube between the hydrogen pressure regulator and the fuel cell gas input is 

required to be less than 30cm.  

3.  The inner diameter of the hydrogen supply tube is required to be more than 2mm.  
4.  The input pressure to the stack is required to be 0.45-0.55Bar. 

 
If the system shuts down by itself check the following details: 
 

1.  Make sure you have connected all wires according to the diagram on page 15. 
2.  Make sure you have a hydrogen input supply at 0.45-0.55Bar to the stack. 
3.  Make sure the load is below 12W. 

 

 
The blower does not run after the stack was connected and supplies with 
hydrogen according to the System set up. 

 
Contact Horizon Fuel Cell Technologies for support.

 

 

The open voltage (no load stack voltage) is less than 9.1V. 
 

1.  Inject water into the stack 

(see Storage and re-use for details)

. And then re-test 

open voltage. 

Note

Make sure you have purged the water out of the stack as much as possible 

before use.

  

2.  Connect a load 5-6W to the stack. And then note the voltage and current to check if 

they comply with our power curve. If not, inject water 

(see Storage and re-use for 

details)

 and then run the stack again. 

3.  If the voltage and current from the 5-6W load comply with the power curve, increase 

the load to 12W. If the voltage and current from the high power load does not comply 
with the power curve, check the hydrogen pressure to the stack and the flow rate. 
Meanwhile purge the stack and then observe the stack. 

4.  Run the stack at 7.8V for 30minutes. If the performance does not go up. Contact 

Horizon Fuel Cell Technologies for support. 

 

Summary of Contents for H-12

Page 1: ...1 Think Big Start Small H 12 Fuel Cell Stack User Manual Updated 08 Dec 2011 H 12_UM_ V2 4_EN...

Page 2: ...tance to disassemble or inappropriately tamper with the fuel cell Operate the fuel cell with valves and blowers that are not provided by Horizon for the specified fuel cell and controller Disassemble...

Page 3: ...Stack and System Component Information 10 4 Technical Specification 11 5 System Performance Curves 12 6 System Set Up 13 6 1 Operating instructions 13 6 2 Simplified Drawings of HFCT Measurement Stand...

Page 4: ...s when the fuel cell stack is energised Do not dismantle the system Contact Horizon if you have any concerns about operation 1 2 Using Hydrogen WARNING FIRE OR EXPLOSION Keep all sources of ignition a...

Page 5: ...any materials considered airtight Fuel lines non welded connections and non metal seals such as gaskets O rings pipe thread compounds and packings present potential leakage or permeation sites Further...

Page 6: ...ce As in the presence of any fuel all sources of ignition including smoking are not permitted in the vicinity of the stack WARNING Keep all sources of ignition away Smoking is not permitted in the vic...

Page 7: ...o not touch individual fuel cells cell voltage monitoring equipment or electrical components WARNING Do not touch fuel cells cell voltage monitoring equipment or electrical components Electronic compo...

Page 8: ...reach 55 C and the cooling air stream can reach 17 C above ambient conditions These temperatures are sufficient to cause burns or severe discomfort Accordingly avoid contact with the fuel cell stack o...

Page 9: ...n the fuel cell the reactants are air and hydrogen by which the electricity will be generated Humidification humidity that the fuel cells need for running Blower supply air to the fuel cells and meanw...

Page 10: ...fuel cells arranged along an axis generally parallel to cell thickness with electrically conductive separator plates between each pair of cells 3 Tube It is used for connecting the pressure regulator...

Page 11: ...emperature 55 C H2 Pressure 0 45 0 55bar Hydrogen purity 99 995 dry H2 Humidification self humidified Cooling Air integrated cooling fan Weight with fan casing 275 grams 30 grams Dimension 7 5cmX4 7cm...

Page 12: ...12 5 Standard System Performance Curves...

Page 13: ...quired to be more than 2mm The input pressure to the stack is required to be 0 45 0 55Bar 2 Disconnect the hydrogen tube from the hydrogen input immediately after the fuel cell stack is shut down Sinc...

Page 14: ...Disconnect the hydrogen tube from the hydrogen input immediately after the fuel cell stack is shut down Since hydrogen gas can leak into the fuel cell and destroy the stack Step 4 Disconnect the red p...

Page 15: ...15 6 2 Simplified Drawings of HFCT Measurement Stand Power V x A...

Page 16: ...then connect it to the hose attached to the stack 3 Inject distilled or purified water into the stack until you see water coming out of another port see picture A below for reference Keep the water in...

Page 17: ...t Horizon Fuel Cell Technologies for support The open voltage no load stack voltage is less than 9 1V 1 Inject water into the stack see Storage and re use for details And then re test open voltage Not...

Reviews: