Eng4 – Roller Diameter Check
1. While in the Engineering Mode Menu, press the Speed “+” or “-” button until Eng4 appears in the
display.
. Press, “Enter” to select.
3. Press Speed “+” or “-” until proper value is reached.
(Please refer to the following chart for value)
4. Press and hold “Start” for 3 – 5 seconds until the console beeps 3 times. The value has now been
properly saved.
Roller Values:
Elite 1.T = 1481
Elite .T = 1481
Elite 3.T = 1481
Elite 4.T = 195
Elite 5.T = 197
Eng5 – Software Change (4.2T and 5.2T Only)
1. While in the Engineering Mode Menu, press the Speed “+” or “-” button until Eng5 appears in the
display.
. Press, “Enter” to select.
3. Press “Enter” to toggle between 4.T and 5.T software versions.
4. Press and hold “Start” for 3 – 5 seconds until the console beeps 3 times. The value has now been
properly saved.
Eng6 – Change from Miles to KM (2.2T, 4.2T, 5.2T Models Only)
1. While in the Engineering Mode Menu, press the Speed “+” or “-” button until Eng6 appears in the
display.
. Press, “Enter” to select
3. Press “Enter” to toggle between Miles and KM software versions (0 = Miles, 1 = KM)
Press and hold “Start” for 3 – 5 seconds until the console beeps 3 times. The value has now been
properly saved.
Engineering Mode Continued
(Models 1.2T, 2.2T, 3.2T, 4.2T, 5.2T)
It is important to verify proper roller values as
improper values can create inaccurate speeds.
To Change the 1.T from miles to KM remove B jumper on back of upper control board.