P
ART
R
EPLACEMENT
Table of Contents
7.0AT-03
45
Service Manual
4. Take photos of the UCB and wire connections so that you can reference them when you are
plugging the wires into the new board.
5. Disconnect all of the wires from the board.
6. Remove the old console overlay set and put the new one in place.
7. Plug the unit into the wall and check for proper function.
a. Check the Go button
b. Check elevation up and down
c. Verify speed up and down
d. Make sure heart rate works
e. Check the Stop button
f. Remove the safety key – the display should show that the safety key is removed
8. If the unit is functioning properly, reinstall the four screws in the back of the console to secure
the front window.
Console Circuit Board Replacement
1. Confirm wearing good contact ESD wrist strap.
2. Remove console set as outlined in above section.
3. Replace the new circuit board.
4. Reverse Steps 2-3.