FG8101G01
Technical Documentation
Page 18 of 49
Version: 01.02; Date: 18.11.2022
7
System mounting FG8101G01
FG8101G01 is designed for installation in a 19" control cabinet. The following steps must
be carried out for installation in the 19" control cabinet:
CAUTION
Thermic
The lateral ventilation openings on the left and right must not be covered.
Otherwise, the ventilation is ineffective and the maximum permissible
operating temperature of the device may be exceeded due to insufficient
convection and/or thermal coupling with surrounding devices.
Fire protection must be ensured in the installed state.
Insert the FG8101G01 into the 19" control cabinet and screw it tight to the front
retaining brackets with 4 screws.
FG8101G01 must be connected to at least one of the two grounding screws
for potential equalization (the positions of the grounding screws are shown in Figure
3). A grounding cable with at least 1.5mm² must be used.
Figure 3
Note
Protection class 1
The system is a protection class 1 device and may only be operated with a
grounded connection.