![hopf 6021GPS Technical Manual Download Page 17](http://html1.mh-extra.com/html/hopf/6021gps/6021gps_technical-manual_2161854017.webp)
R
EMOTE
S
OFTWARE
6021GPS GPS Satellite Clock - V01.00
17 / 41
hopf
Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
3.6 Time Window
All of the time and status information of the Board 6021GPS is displayed or set in the Time
window.
3.6.1 Time
All of the current time information/status is displayed under the Time tag.
The
<= PC-Time
button can be used to set the new time information in accordance with
the current PC time.
Value range
Optical Coupler Status
SYNC
Time synchr Quartz control started/running
SYOF
Time synchr SyncOFF running
SYSI
Time synchronized as simulation mode
(without actual GPS reception)
QUON
Quartz/crystal time + SyncON running
QUEX
Quartz/crystal time (in freewheel after synchronization
failure
Ö
Board was already synchronized)
QUSE
Quartz/crystal time after reset or manual setting
INVA
Invalid time