1
1
Safety Precautions
This chapter describes the safety precautions to be observed during the installation, operation
and maintenance of inverter. Please carefully read the safety precautions before the installation,
maintenance and other operations of inverter. All personals must strictly observe safety
precautions during the operation. Personal injury or damage to inverter and associate devices
may occur if the safety precautions are ignored.
When operating the inverter, please pay particular attention to the following items:
1.
Only qualified professionals can install, operate and maintain the inverter.
2.
Please avoid toppling and knocking the inverter cabinet during moving the inverter.
3.
Prevent liquid, debris or chippings from getting inside the inverter; a conductive fluid and debris may cause
an internal short circuit of inverter and result in equipment damage.
4.
Before completing installation and maintenance, the inverter must be isolated from power grid and other
electrified devices.
5.
Please make sure that relevant protective measures have been taken to avoid electric shock, fire or other
accidents.
Don't place explosive and inflammable substances around the inverter!
1.1 Transportation
1.
Please keep the inverter well packed and upward, avoid strong shock or collision during the transportation.
2.
Please transport the inverter with package and operate in accordance with the signs and labels during the
transportation. Please refer to "2.6 Signs and labels" for detailed information.
3.
Please ensure the transportation environment can meet the requirements. Please refer to "2.10 Ambient
Requirements" for detailed information.
1.2 Storage
The storage environment of inverter should meet the corresponding requirements. Please refer to "2.10
Ambient Requirements" for detailed information.
About long-term storage:
Before or after the installation, it's regarded as long-term storage if the inverter has been in the no power
supply status for over three weeks. Please pay attention to the following issues about long-term storage:
Put the desiccant into several equipment cabinets and pack the inverter with packaging materials;
Attention must be paid to ventilation and moisture prevention where equipment is stored and any water is
strictly prohibited;
Necessary measures must be taken to deal with adverse environments, such as abrupt cooling and
heating, collision and dust storm to prevent damages to the inverter.
Regular inspection at least once a week, inspect whether the package is intact and prevent it from
damages caused by insects and rats. Please replace the damaged package immediately.
The inverter shall be unpacked, inspected, repacked, and replace the new desiccant if it is stored for over