background image

06 GB

The hob may be installed in any worktop which is heat resistant to a 
temperature  of  100°C,  and  has  a  thickness  of  25-45  mm.  The 
dimensions of the insert to be cut out of the worktop are in shown in

 

Figure 2.

If  the  Hob  is  fitted  next  to  a  cabinet  on  either  side,  the  distance 
between the Hob and the cabinet must be at least 15 cm 

(see Figure 

4)

; while the distance between the hob and the rear wall must be at 

least 5,5 cm.
The distance between the hob and any other unit or appliance above it 
(e.g. An extractor hood) must be no less than 70 cm

 (Figure 4)

.

When there is an accessible space between the built-in hob and the 
cavity  below,  a  dividing  wall  made  of  insulating  material  should  be 
inserted (wood or a similar material)

 (Figure 3).

Important - The diagram in figure 1 shows how the sealant should 
be applied.

The Hob unit is fitted by attaching the Fixing Clamps supplied, using 
the holes at the base of the unit.
If a hob of 60 cm is fitted above an oven which is not equipped with fan 
cooling system it is recommended that openings are created within 
the built in furniture to ensure correct air circulation.
The size of these openings must be at least 300 cm2 and placed as 
shown in 

Figure 5.

When a 75 cm hob is fitted over a built in oven, the latter must be fan 
cooled.

1.1 BUILDING IN

1.2. SUITABLE LOCATION

This appliance must be installed in accordance with the regulations in 
force and only used in a well ventilated space. Read the instructions 
before installing or using this appliance.

A gas-powered cooking appliance produces heat and humidity in the 
area in which it is installed. For this reason you should ensure good 
ventilation  either  by  keeping  all  natural  air  passages  open  or  by 
installing  an  extractor  hood  with  an  exhaust  flue.  Intensive  and 
prolonged use of the appliance may require extra ventilation, such as 
the opening of a window or an increase in speed of the electric fan, if 
you have one. 
If a hood can not be installed, an electric fan should be fitted to an 
outside wall or window to ensure that there is adequate ventilation.
The electric fan should be able to carry out a complete change of air in 
the  kitchen  3-5  times  every  hour.  The  installer  should  follow  the 
relevant national standards.

2. ELECTRICAL CONNECTION 

(FOR U.K. ONLY)

Warning - this appliance must be earthed

This appliance is designed for domestic use only. Connection to the main 
supply must be made by a competant electrician, ensuring that all current 
regulations concerning such installations are observed.
The appliance must only be connected to a suitably rated spur point, a 
3 pin 13 amp plug/socket is not suitable. A double pole switch must be 
provided  and  the  circuit  must  have  appropriate  fuse  protection. 
Further details of the power requirement of the individual product will 
be found in the users’ instruction and on the appliance rating plate. In 
the case of built-in product you are advised, should you wish to use a 
longer cable than the one supplied, that a suitably rated heat resistant 
type must be used.

The wiring must be connected to the mains supply as follows:

CONNECT

 

TO SPUR TERMINAL

Green & Yellow Wire 

Earth Connection

Blue Wire 

Neutral Connection

Brown Wire 

Live Connection

Note:

  We  do  not  advocate  the  use  of  earth  leakage  devices  with 

electric  cooking  appliances  installed  to  spur  points  because  of  the 
«nuisance tripping» which may occur. You are again reminded that the 
appliance must be correctly earthed, the manufacturer declines any 
responsibility for any event occurring as a result of incorrect electrical 
installation.

2.1. ELECTRICAL CONNECTION 

Check the data on the rating plate, located on the outside of the unit, to 
ensure that the supply and input voltage are suitable.
Before connection, check the earthing system.
By Law, this appliance must be earthed. If this regulation is not complied 
with, the Manufacturer will not be responsible for any damage caused to 
persons  or  property.  If  a  plug  is  not  already  attached,  fit  a  plug 
appropriate to the load indicated on the rating plate. The earth wire is 
coloured yellow/green. The plug should always be accessible.
Where the Hob is connected direct to the electricity supply, a circuit 
breaker must be fitted.
If the power supply cord is damaged this is to be replaced by a qualified 
engineer so as to prevent any potential risk.
The earth wire ( green and yellow coloured ) must be at least 10 mm 
longer than the live and neutral wires.
The section of the cable used must be of the correct size in relation to 
the absorbed power of the hob.
Please  check  rating  plate  for  the  power  details  and  ensure  that  the 
power supply cord is of the type 3x0.75 mm² H05RR-F.

LIVE
EARTH
NEUTRAL

L

N

Power Cable

Brown Wire

Green/Yellow Wire
Blue Wire

Mains Supply

If an appliance is not fitted with a supply cord and a plug, or with other 
means  for  disconnection  from  the  supply  mains  having  a  contact 
separation in all poles that provide full disconnection under overvoltage 
category  III  conditions,  the  instructions  shall  state  that  means  for 
disconnection must be incorporated in the fixed wiring in accordance with 
the wiring rules.

The flexible tube shall be fitted in such a way that it cannot come into 
contact with a moveable part of the housing unit (e.g. a drawer) and does 
not pass through any space where it may become crushed/ kinked or 
damaged in any way.

To  prevent  any  potential  damage  to  the  hob  please  carry  out  the 
installation following this sequence (picture 6):

1)As illustrated, assemble parts in sequence:

A: 1/2 Male Adaptor Cylindirical
B: 1/2 Seal
C: 1/2 Female Gas Adaptor Conical-Cylindirical or 
     Cylindirical-Cylindirical

2)Tighten the joints with the spanner, remembering to twist the 
pipes into position.

3)Attach fitting C to mains gas supply using rigid copper pipe or 
flexible steel pipe.

IMPORTANT:  carry  out  a  final  check  for  leaks  on  the  pipe 
connections using a soapy solution. 

NEVER USE A FLAME. 

Also, 

make sure that the flexible pipe cannot come into contact with a 
moving part of the cabinet (eg.adrawer) and that it is not situated 
where it could be damaged.

Warning: 

If gas can be smelt in the vicinity of this appliance turn off the 

gas  supply  to  the  appliance  and  call  the  engineer  directly.  Do  not 
search for a leak with a naked flame.

When  connecting  the  hob  to  the  gas  supply  via  use  offlexible  hoses 
please ensure that the maximum distance covered by the hose does not 
exceed 2 metres.

1. INSTRUCTIONS FOR THE INSTALLER

INSTALLING A DOMESTIC APPLIANCE CAN BE A COMPLICATED OPERATION WHICH IF NOT CARRIED OUT CORRECTLY, CAN SERIOUSLY 
AFFECT CONSUMER SAFETY. IT IS FOR THIS REASON THAT THE TASK SHOULD BE UNDERTAKEN BY A PROFESSIONALLY QUALIFIED 
PERSON WHO WILL CARRY IT OUT IN ACCORDANCE WITH THE TECHNICAL REGULATIONS IN FORCE. IN THE EVENT THAT THIS ADVICE IS 
IGNORED AND THE INSTALLATION IS CARRIED OUT BY AN UNQUALIFIED PERSON, THE MANUFACTURER DECLINES ALL RESPONSIBILITY 
FOR ANY TECHNICAL FAILURE OF THE PRODUCT WHETHER OR NOT IT RESULTS IN DAMAGE TO GOODS OR INJURY TO INDIVIDUALS.

Summary of Contents for 33801522

Page 1: ...OU IT CZ TABLES DE CUISSON NOTICE D EMPLOI FR UND BEDIENUNGSANLEITUNG INSTALLATIONS DE ENCIMERAS INSTRUCCIONES DE USO ES INSTRUKCJE U YCIA I MONTA U PL ANKASTRE OCAK KULLANIM KLAVUZU TR NAVODILA ZA UP...

Page 2: ...2 4 Regulaci n De La Llama M nima 3 Utilizaci n De La Placa Instrucciones Para El Usuario 3 1 Utilizaci n Del Quemador De Gas 4 Mantenimiento Y Limpieza 5 Servicio T cnico 6 Protecci n Del Medioambien...

Page 3: ...Rede De G s 2 3 Adapta o Da Placa A Diferentes Tipos De G s 2 4 Regula o Da Altura M nima Da Chama 3 Utiliza o Da Placa Instru es Para O Utilizador 3 1 Como Utilizar O Queimador De G s 4 Manuten o E L...

Page 4: ...cessible space Figure 3 Min 10 mm Sp da 25 a 45 mm Figure 2 Figure 1 2 60 cm 2 240 cm 2 120 cm 2 180 cm Figure 5 Figure 4 1 2 GAS CONICAL C A B CYLINDRICAL CONICAL INJECTOR Figure 6 Figure 7 Figure 8...

Page 5: ...a special cord or assembly available from the manufacturer or its service agent CAUTION In order to avoid a hazard due to inadvertent resetting of the thermal cutout this appliance must not be suppli...

Page 6: ...that the appliance must be correctly earthed the manufacturer declines any responsibility for any event occurring as a result of incorrect electrical installation 2 1 ELECTRICAL CONNECTION Check the...

Page 7: ...0 28 30 mbar LPG 73 g h 127 g h 182 g h 255 g h 291 g h These instructions are for qualified personnel installation of equipment must be in line with the relevant national standard For U K only by law...

Page 8: ...out modifications to products as required including the interests of consumption without prejiudice to the characteristics relating to safety or function Declaration of compliance This equipment in t...

Page 9: ...ntation est endommag il doit tre remplac par un cordon sp cial disponible aupr s du fabricant ou de stations de d pannage agr es ATTENTION Pour viter tout danger d une r initialisation accidentelle ce...

Page 10: ...s qui pourraient survenir l usage d un appareil non reli la terre ou reli une terre dont la continuit serait d fectueuse V rifier les donn es sur la plaque signal tique situ e l ext rieur de l unit po...

Page 11: ...nt du gaz si la flamme est accidentellement teint les br leurs sont allum s et d crit ci dessus mais il faut prendre soin de garder la manette de commandes enfonc e pendant 5 ou 6 secondes apr s que l...

Page 12: ...ne toute responsabilit concernant d ventuelles inexactitudes imputables des erreurs d impression ou de transcription contenue dans cette notice Le constructeur se r serve le droit de modifier les prod...

Page 13: ...nika UPOZORN N abyste zabr nili nebezpe z ne mysln ho resetov n tepeln pojistky tento spot ebi nesm te nap jet p es extern sp nac za zen jako je asova nebo p ipojovat k obvodu kter se pravideln zap n...

Page 14: ...ejm n o 10 mm del ne iv a neutr ln vodi Pou ijte vhodn kabel podle parametr v konu trouby Zkontrolujte v robn t tek a ujist te se zda je p vodn kabel typu 3x0 75 mm H05RR F iv Uzemn n Neutr ln L N P v...

Page 15: ...n ho k Dvouokruhov ho k A SR R UR QC 12 18 18 24 24 26 24 28 24 28 V kon kW G20 20 mbar Metan G30 28 30 mbar LPG 1 00 1 75 2 50 3 50 4 00 95 I h 167 I h 238 I h 333 I h 381 I h 73 g h 127 g h 182 g h...

Page 16: ...0 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 15 W 15 W 15 W 15 W 15 W 15 W 15 W 15 W 595 x 510 595 x 510 745 x 510 745 x 510 745 x 510 Triple Crown ho k TC Mono...

Page 17: ...besch digt muss es durch ein spezielles Kabel ersetzt werden welches beim Kundendienst Hersteller erh ltlic ist ACHTUNG Um elektrische Schl ge durch unbeabsichtigtes Zur ckstellen des W rmerelais zu...

Page 18: ...ngaben in einem eventuellen Servicefall vom Kundendienst ben tigt werden berpr fen Sie dass die Netzspannung und die Leistung f r den Betrieb des Ger tes geeignet sind Vor dem elektrischen Anschluss i...

Page 19: ...eingeschaltet und die Flamme bleibt stabil ACHTUNG Bevor Sie das Gaskochfeld einschalten berpr fen Sie dass die Brenner richtig aufliegen und die Funktion der Z ndkerzen nicht beeintr chtigen ALLGEME...

Page 20: ...meln muss solange das Ger t von dem gleichenTyp ist und dieselben Funktionen hat wie das gelieferte Ger t 6 UMWELTGERECHTE ENTSORGUNG Konformit tserkl rung Dieses Ger t entspricht in den Teilen die mi...

Page 21: ...est da ado se debe sustituir por un cable o conjunto especial suministrado por el fabricante o el servicio t cnico PRECAUCI N Con el fin de evitar peligros derivados de alteraciones en el suministro e...

Page 22: ...INSTALADOR LA INSTALACI N DE UN ELECTRODOM STICO PUEDE SER UNA OPERACI N QUE PUEDE AFECTAR GRAVEMENTE A LA SEGURIDAD DEL USUARIO SI NO SE REALIZAADECUADAMENTE POR ELLO ES UNA TAREA QUE HA DE REALIZAR...

Page 23: ...que interrumpe el flujo de gas si la llama de apaga por accidente los quemadores se encienden como se describe arriba pero ha de mantenerse pulsado el mando durante 5 o 6 segundos una vez prendida la...

Page 24: ...d o el funcionamiento Declaraci n de cumplimiento en este equipo las piezas que se prev que puedan estar en contacto con los alimentos cumplen las regulaciones de la CEE indicadas en la directiva 89 1...

Page 25: ...cymi przepisami instrukcja musi okre la jaki rodzaj przewodu mo e by zastosowany z uwzglednieniem temperatury tylnej cianki urz dzenia Je eli przew d zasilaj cy jest uszkodzony nale y go wymieni na no...

Page 26: ...i dostosowanej do mocy pobieranej przez p yt FAZOWY UZIEMIENIE NEUTRALNY L N Kabel zasilaj cy Przew d br zowy Przew d tozielony Przew d niebieski Zacisk sieci zasilaj cej Wy cznik musi by pod czony do...

Page 27: ...zyma w pozycji wci ni tej przez 5 do 6 sekund A SR R UR QC 12 18 18 24 24 26 24 28 24 28 Moc kW G20 20 mbar Metan G30 28 30 mbar LPG 1 00 1 75 2 50 3 50 4 00 95 I h 167 I h 238 I h 333 I h 381 I h 73...

Page 28: ...o usuni cia i pozbycia si wszystkich rodk w zanieczyszczaj cych i odzyskania wszystkich surowc w wt rnych Poszczeg lne osoby odgrywaj wa n rol w zapobieganiu szkodliwemu oddzia ywaniu zu ytego sprz tu...

Page 29: ...acak prizin tipi cihaz n arka k sm ndaki s cakl k d n lerek belirtilmelidir Elektrik kablosu hasarl ise zel bir kablo ya da retici veya yetkili servisin uygun g rd kablo ile de i tirilmelidir Uyar Ter...

Page 30: ...yna kablosunun 3x0 75 mm H05RR F tipinde olmas n sa lay n AKT F TOPRAK NOTR L N G Kablosu Kahverengi Kablo Ye il Sar Kablo Mavi Kablo Ana G Kayna Ba lant n n sa lanamamas kablolama kurallar na g re ka...

Page 31: ...TabloA Daha k k kaplar i in gaz oca g zlerinin alevin tavan n taban n a mayacak ekilde ayarlanmas gerekir Konkav veya konveks tabanl kaplar kullan lmamal d r UYARI Ocak yanl l kla s nd r l rse d meyi...

Page 32: ...ur Uygunluk Beyan Bu ekipman g dalarla temas etti i par alarda 89 109 say l EEC Direktifinde ng r len d zenlemelere uygundur Bu cihaz 2009 142 EC say l Avrupa Direktiflerine ve sonraki de i ikliklere...

Page 33: ...lar n n kullan lmas ile ilgili olarak kabilecek uyu mazl klarda yerle im yerinin bulundu u veya t ketici i leminin yap ld yerdeki T ketici Hakem Heyetine veya T ketici Mahkemesine ba vurabilir Garanti...

Page 34: ...34 RU 8 8...

Page 35: ...1 2 3 5 3 13 2 2 1 10 3x0 75 mm HO5RR F 35 RU L N I III 100 25 40 2 15 4 5 5 70 4 3 1 60 300 2 5 75 1 1 2 2 Gas Safe 1...

Page 36: ...4 9 3 4 3 3 1 36 RU A cm AUX SR R UR QC 12 18 18 24 24 26 24 28 24 28 G20 20 G30 28 30 1 00 1 75 2 50 3 50 4 00 95 167 238 333 381 73 127 182 255 291 5 0 8 CY 2 6 1 1 2 1 2 1 2 2 3 24 28 3 80 362 l h...

Page 37: ...3 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 15 W 15 W 15 W 15 W 15 W 15 W 15 W 15 W 595 x 510 595...

Page 38: ...je potrebno upo tevati temperaturo na hrbtni strani aparata e je priklju ni elektri ni kabel po kodovan ga je treba zamenjati z enakovrednim ali sklopom ki vam je na voljo pri poobla enem servisu POZ...

Page 39: ...Ozemljitev Nula L N priklju ni kabel rjava ica zelena rumena ica modra ica Napajanje Pri fiksni priklju itvi mora biti zagotovljena mo nost izklopa iz elektri nega omre ja skladno z veljavnimi predpis...

Page 40: ...s podatki o vrsti plina z ustrezno prilo ena kuhalni plo i tako da se bodo podatki ujemali z vrsto plina za katero je kuhalna plo a prilagojena 4 VZDR EVANJE IN I ENJE Pred i enjem po akajte da se vs...

Page 41: ...V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 220 240 V 50 60Hz 15 W 15 W 15 W 15 W 15 W 15 W 15 W 15 W DA DA DA DA DA DA DA DA 595 x 510 595 x 5...

Page 42: ...ere sostituito da un cavo o un assieme speciali disponibili presso il costruttore o il suo servizio assistenza tecnica ATTENZIONE Al fine di evitare ogni pericolo dovuto al riarmo accidentale del disp...

Page 43: ...ottura sia connesso direttamente all alimentazione principale bisogner predisporre anche un salvavita Se il cavo di alimentazione danneggiato dovr essere sostituito da personale qualificato in modo da...

Page 44: ...rgenti corrosivi agenti sbiancanti o acidi Evitare ogni tipo di acido o sostanza alcalina limone aceto etc per pulire le parti smaltate laccate o in acciao inox Quando bisogna pulire le parti smaltate...

Page 45: ...W 15 W 15 W S S S S S S S S 595 x 510 595 x 510 745 x 510 745 x 510 745 x 510 Bruciatore tripla corona TC Mono 135 mm S67 HBGPL2X S67 HBGPL2X S67 HBGPL2X S S S 1 1 1 1 1 1 1 1 1 1 2 1 9 05 kW 11 55 kW...

Page 46: ...registada na superf cie traseira do aparelho Se o cabo de alimenta o estiver danificado tem de ser substitu do por um cabo ou conjunto especial que pode ser obtido junto do fabricante ou do seu servi...

Page 47: ...ompletamente o ar no interior da cozinha 3 a 5 vezes por hora O instalador deve cumprir todos os regulamentos e normas nacionais aplic veis 2 2 LIGA O REDE DE G S Estas instru es destinam se a pessoal...

Page 48: ...chama piloto tem de ser rodado para a direita at prender Depois de ter regulado a placa para o tipo de g s que vai ser utilizado substitua a placa de caracter sticas antiga com os dados relativos ao...

Page 49: ...REEE dever o ser entregues nos pontos de recolha relevantes geridos pelo munic pio ou por empresas registadas Em muitos pa ses no caso de grande REEE poder o existir servi os de recolha ao domic lio...

Page 50: ...W Min kW AUX SR R UR QC 1 00 1 75 2 50 3 50 3 50 0 25 0 40 0 60 1 20 1 75 P Kw 0 95 Y 1 21 Y 1 45 F2 1 70 7 1 90 II2HS3B P Gaz tipusa G20 Gaz nyomasa 25 mbar Max kW Min kW AUX SR R UR QC 1 10 1 90 2 7...

Page 51: ...e gazu G z nyom sa Gaz Bas nc 20 mbar Max kW Min kW AUX SR R UR QC 1 00 1 75 2 50 3 50 4 00 0 25 0 40 0 60 1 20 1 75 0 72 X 0 97 Z 1 09 Y 1 40 H3 1 45 CY CZ GB GR IE IT PT SI ES CH TR P Kw Tipo di gas...

Page 52: ...hweiz AT DE CH G30 31 50 mbar 3B P Beim Gastyp G30 31 50 mbar 3B P dagegen m ssen die Gasd sen Art Nr benutzt werden Bitte bestellen Sie die e n t s p r e c h e n d e n G a s d s e n s t z e bei unser...

Page 53: ...nie z potrzebami w tym w interesie konsumenta bez szk d dla charakterystyk dotycz cych bezpiecze stwa lub dzia ania TR retici bu klavuzda meydana gelecek bask hatalar ndan sorumlu de ildir retici gere...