background image

 

                                        

                                      

Shepherd 210A Operation Manual V1.1                      

©Copyright 2004. Hongda USA Inc.

 

 

 

8

5.9.  When 2 beeps sound, that person’s fingerprint was successfully 

registered. 

 

The display should show 03 – 11 – 07.  (The next available 

Supervisor ID is now 07 since you just used up 06) 

 

5.10. 

If 3 beeps sound, the registration was not successful.  You can 

immediately press 

STOR

 until a long beep (about 3 seconds) and try 

again from Step 5.8 above.  However, if the power has Timed Out, 

and you hear the motor sound, then you must start over from Step 5.4 

above. 

5.11. 

After a successful registration, you can immediately register 

another person starting with Step 5.5 above, or if Timed Out, start at 

Step 5.4. 

5.12. 

After registrations, wait about 10 seconds for the lock to Time 

Out before trying to test the fingerprint access system. 

 

 

 

 

Summary of Contents for Shepherd 210A

Page 1: ...epherd 210A Fingerprint Door Lock Operations Manual V1 1 Hongda USA Inc 2505 Technology Dr 2 6A Hayward CA 94545 USA Phone 510 887 5682 Fax 510 372 0487 Email info hongdausa com Website www hongdausa com ...

Page 2: ...g Security Threshold Level 7 4 Registering Fingerprints 9 5 Unlocking the door with your fingerprint 11 6 Display 12 7 Registering additional fingerprints 12 8 Deleting Fingerprints 15 9 Door Operation 16 10 LED Display 20 11 Troubleshooting 20 12 Specifications 23 13 User ID List 24 ...

Page 3: ... As with many advanced technologies the use of biometrics for identification involves a learning process The Shepherd 210 uses exciting technology and design that allows the opening of a locked door simply by pressing a finger on the lock but users must learn the best positioning and pressure to use 1 2 Generally the center of the vortex of the fingerprint pattern is the key data point ideally it ...

Page 4: ...r the risk of scratching the window 1 3 The Shepherd 210 allows setting of security thresholds to determine how precisely you must place your finger to open the lock thus giving customers a range in the tradeoff between security and convenience 1 4 The attractive dust cover is just that It has no effect on the electronic system and can be removed if the lock is installed on an inside door where du...

Page 5: ...hape is unmarked The Inside part also has an Unlock button to retract the deadbolt There are also three programming buttons STORE DELETE and SELECT on Inside of lock Figure 1 Store Delete Select Lock Unlock Pull Power On Lock Deadbolt Registering or Programming of Fingerprints This is the process of acquiring the image of fingerprints of authorized persons and storing them into the lock s memory A...

Page 6: ...ion Error Reference source not found 1 3 Security Levels Five thresholds are available to optimize between convenience in operating lock versus stringency of security in matching fingerprint images Section Error Reference source not found 1 4 Management Levels The Shepherd 210 has three permission levels Administrator Supervisor and User They are designated and identified by ID numbers that corres...

Page 7: ... new registrants will be assigned ID numbers as Users i e IDs 11 through 50 This is because for most applications only two management levels are needed Administrator and User Administrator IDs 1 5 Supervisor IDs 6 10 User IDs 11 50 Mass erase X Add same level X Delete same level X Add below level X X Delete below level X X Open door X X X Check current ID X X X ...

Page 8: ...r to using the lock At S4 the fingerprint image must match perfectly with a registered fingerprint which means there is no risk of a false acceptance but the users must learn to place their fingers consistently and present an excellent image in order to be admitted S1 S2 and S3 are intermediate levels 1 2 Setting Security Threshold Levels 1 2 1 If no fingerprints have been registered press Power b...

Page 9: ...1 2 5 If fingerprints are already registered and stored it is necessary for an Administrator to first access the lock with his her fingerprint then proceed with the three buttons per Step 1 2 2 above 1 2 6 Only one security level is set for the lock at a time Different security levels cannot be set for different individuals ...

Page 10: ...buttons 2 4 On the first two registrations there is no need to assign management levels as they will be Administrators automatically but on subsequent registrations have in mind what level you wish to assign and the range of ID numbers defining the levels Review Para Error Reference source not found above 2 5 Hint Before starting the procedure for registration decide on what finger you wish to use...

Page 11: ...as successfully registered 2 6 7 If you hear THREE beeps the fingerprint was NOT registered due to a poor image movement or other reasons Start at Step 2 6 2 and try again if you heard a motor noise and the power has timed out If power is still on start over at Step 2 6 3 2 7 After registration test to see that you can activate the lock per the next section before you shut the door and maybe lock ...

Page 12: ...flash and hear a noise indicating the door mechanism is being activated after accepting a proper fingerprint 3 4 If there are three beeps the fingerprint was rejected This means the finger was positioned and or pressed in a way that did not match the registration Simply press the Power On button again and place your finger again With a little practice you will unlock the door every time Note Secti...

Page 13: ...an verify the ID of the person who just unlocked the lock Immediately after a fingerprint verification press the Select button The Display will then show the entering ID alternating with the remaining number of available spaces in the lock memory For example if there are two Administrators and the last of four Users just entered the display would show 04 44 5 Registering additional fingerprints 5 ...

Page 14: ...ring a third person pressing repeatedly on the Select button will display 11 06 03 These are the next available IDs in the three categories If you wish this person to be at the Supervisor level for example you would cycle the three available choices to 06 the next available ID number in the Supervisor category Note The ID number must be selected at this time A fingerprint image cannot have its man...

Page 15: ... not successful You can immediately press STOR until a long beep about 3 seconds and try again from Step 5 8 above However if the power has Timed Out and you hear the motor sound then you must start over from Step 5 4 above 5 11 After a successful registration you can immediately register another person starting with Step 5 5 above or if Timed Out start at Step 5 4 5 12 After registrations wait ab...