A complete Transmitter Menu Map is shown in Appendix C. Below is an
overall view of the configuration menu to aid the user in setting up the
Transmitter for proper operation.
Figure 4.3: Overall Configuration Menu Map
4.2: Overall Configuration
Menu Map
NOTE
The user must enter a four-digit password to enter
the CONFIG and DIAGNSE menus. The FAC-
TORY menu is for factory use only. The default
user password is 0000. For more information
about the password, see Section 4.4.
Each Transmitter also has a user-settable Transmitter Tag Name. This tag
name is displayed upon Transmitter power up, and when the Read Only
Sequence is selected. The Tag Name is a 21-character string that is dis-
played in three separate 7-character flashes on the Transmitter LCD.
The user may choose from A-Z, 0-9, a dash (“-“), and an underscore (“_”).
The underscore has a special meaning to the software inside the Transmit-
ter. For example, if you have a Tag Name that is only 5 characters long,
then you do not want to wait for the rest of the 16 characters to be dis-
played on the LCD. So if your Tag Name was “TANK1”, you would want
to enter the Tag Name like this: “TANK1_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _”.
The Tag Name can also be entered via WMT. To do so, when the software
is in the Transmitter view (See Appendix A), right-click the Transmitter
icon, select Rename, and then enter the Tag Name you wish the Transmit-
ter to have.
This Tag Name will then be uploaded to the Transmitter and can be dis-
played by pressing the ENTER button when the unit is in the Operations
Sequence (See Section 4.1.1 of this manual).
Figure 4.4: Menu Map to Tag Name Setting
4.3: Setting the Transmitter Tag
Name*
* Indicates that Menu is Disabled if Wireless Management Toolkit is detected. (See Appendix A)
Using Wireless Management Toolkit