background image

CHAPTER

2

WEBs HMI Touchscreen Monitor - User Guide

2

FIRST & QUICK START OF DEVICE

First start of the device

After starting up the device for the first time, you are located on the settings page. 

Therefore, user need to login to the Setup menu to configure the device. By default, 

the username and password are 

admin

After entering the configuration menu for the first time, the user is forced to 

change the admin password. This password must follow security requirements and 

must be remembered all the time to be able to change the configuration of the 

device. New password: _____________________________________________________  

Summary of Contents for WEB-HMI Series

Page 1: ...User Guide WEB HMI Touchscreen Monitors ...

Page 2: ...nal Inc Other Trademarks Third party brands and names are the property of their respective owners Microsoft Win32 Windows Windows XP Windows Vista Windows 7 Windows 8 Visual Studio are either registered trade marks or trademarks of the Microsoft Corporation in the United States and other countries Other products and company names mentioned herein may be the trademarks of their respective owners Th...

Page 3: ...WEBs HMI Touchscreen Monitor User Guide III ...

Page 4: ...System Settings 8 Open the System settings menu 8 The system settings 8 Localisation 9 System 9 Logs 9 Date Time 10 Network 11 Services 11 Management 12 Display 12 Fonts 12 Authentication 14 Restart 14 Web Browser 14 Exit 15 Chapter 4 Factory Reset 16 Factory reset 16 Reset Procedure 16 Create the recovery USB device 16 Chapter 5 SOFTWARE AND FIRMWARE UPDATES 18 Firmware Update 18 Updating the BSP...

Page 5: ...scribes how to use WEB HMI touch screen monitors and it also pro vides information on the features and functionalities common to all the variants of the monitors The product specification and installation are beyond the scope of this guide Related Documents Document Title Document Number Description WEBs HMI Touchscreen Monitor Product Data 31 00389 This document is intended for all users to know ...

Page 6: ...ed to login to the Setup menu to configure the device By default the username and password are admin After entering the configuration menu for the first time the user is forced to change the admin password This password must follow security requirements and must be remembered all the time to be able to change the configuration of the device New password ____________________________________________...

Page 7: ...s Wait for the device to reboot and display the Login screen again Enter admin in the Username box Configuration of the web client The Settings Page The settings page is the default start page Enter the credentials to open the configuration menu or press Load Homepage on the top right of screen to access the configuration done in the web browser setup If you download a new application you can forc...

Page 8: ...pplication tap and hold the top left corner of the touchscreen for 5 seconds to open the settings page The Web Browser Settings After entering the configuration menu Web Browser System Settings panel dis plays To change the web Browser configuration press EDIT on the right top on the page 5 seconds ...

Page 9: ...utomatically requested from the DHCP server If no DHCP server is available or can t be used on site the configuration can be changed to static IP To configure the network interface open the Network tab and press the EDIT button on the top right Item Default Description On Startup Open settings page After a restart of the device the setting page displays Continue where you left Jump to the applicat...

Page 10: ...work traffic including Internet Control Message Protocol ICMP ping requests Therefore you cannot ping the device to test the network connectivity Finish Quick start The device is now configured to load the homepage you entered Therefore you can close the setup menu to access the homepage by clicking EXIT in the System Settings view Depending on the Web Browser configuration On Startup the applicat...

Page 11: ...ystem information Status and Timers Logs Configure log file generation Date Time Configure the date and time of the device Network Configure the network settings of the Ethernet interfaces Services Use to enable the network bridge Management Firmware updates and basic FW and booter configurations Display Display setup like colors timeouts and touch screen calibration and more Fonts Use to install ...

Page 12: ...t the persistent log option if you want to maintain the log files saved after a power reset Note The log file manager cyclically fills 3 files of 4Mb Save Use save button to export a copy of the log files This option allows the log file s to be saved to an external storage device e g USB device Note Log file entries are timestamped with the HMI panel date and time settings Parameter Description In...

Page 13: ...ce on a PC and navigate to the logs tar gz file Step 2 Using a suitable tool e g 7 Zip open the file to reveal a file called logs tar Step 3 Open the logs tar file to view its contents Date Time Provides access to the HMI panel date and time and to setup NTP operation if required Currently HMI panel only makes use of date and time settings to provide an accurate timestamp to entries in the log fil...

Page 14: ...eth0 Enabled Off default On default Type SW Bridge br0 is the default and only option Network Interfaces eth0 eth1 eth2 select which Ethernet ports are active Parameter Description General Settings Device hostname Avahi Hostname Network Interface Network parameters of the available interfaces Name eth0 eth1 or eth2 Label WAN LAN1 or LAN2 MAC Address DHCP enabled or disabled Address current IP addr...

Page 15: ...onts from here Install additional fonts Step 1 Select sign to add a new font The following dialogue box is displayed Caution Working in the Management area is a critical operation and when not performed correctly may damage product requiring service of the product Contact technical support for assistance Use the Clear command inside the Data section to remove HMI Runtime from the device Factory Re...

Page 16: ...d select it Step 6 Select Ok The following screen will be displayed Step 7 Select PROCEED The selected font will now be installed on HMI panel Note Each style of a font e g regular bold italic bold italic etc requires a separate font file Step 8 Unplug the USB device when finished To remove a custom font Step 1 Access the System Settings screen Step 2 Select Fonts Step 3 Select Custom Fonts to vie...

Page 17: ...re you left Option not supported Open homepage The specified Homepage is displayed The HMI panel login page does not appear Homepage The primary web page to be displayed when On Startup Open Homepage is selected or when Load Homepage is selected from the login screen For example https 192 168 0 85 Fallback page If enabled this allows a secondary webpage to be specified which will be displayed if t...

Page 18: ...screen virtual keyboard Once the Virtual keyboard option is disabled the only way to enter text will be by using a keyboard connected to one of the HMI panel USB ports Enable password management When enabled the web browser will prompt the user to save any passwords entered for the connected site The next time that the user accesses the site HMI panel will auto fill the saved password Changing thi...

Page 19: ... touch screen until TAP TAP DETECTED appears on the top of the screen Step 3 Remove the finger from the touch screen The is pointing to SYSTEM SETTINGS Step 4 Wait 5 seconds until ENTERING SYSTEM SETTINGS Step 5 Touch and hold the screen The is pointing to DEVICE RESTORE Step 6 Hold the touch screen until the device starts resetting Create the recovery USB device Format the device with a FAT32 fil...

Page 20: ...e Chromium Browser Always ensure that the latest BSP and Application is installed on the product Updating the BSP 1 Put the new BSP firmware files into the root directory of a FAT formatted USB Stick 2 Enter ConfigOS There are two ways to enter ConfigOS to update the BSP components a Via Admin Area i Enter the Admin Area ii Open Restart tab on the left side iii Select ConfigOS and confirm reboot b...

Page 21: ...update process of the corresponding part 6 Insert the USB stick Until the product beeps Then press the Browse Image button 7 Browse to usbmemory and select the image to install 8 Press Proceed to install the update Updating the Chromium Application 1 Put the new application files into the root directory of a FAT formatted USB Stick 2 Boot into System Settings a Power cycle the device b Keep tappin...

Page 22: ... 3 Press the Startup Sequence button 4 Authentication with admin user 5 Open tab Management 6 On the Installed Apps list select Chromium and press the uninstall Button 7 Insert the USB stick Until the product beeps Then press the Install button ...

Page 23: ...Touchscreen Monitor User Guide 8 Browse to mnt usbmemory location and select the image to install un6x chromium xx x x zip 9 After the installation is complete press the Done button to execute the restart sequence ...

Page 24: ... Honeywell Building Technologies Honeywell 715 Peachtree street NE Atlanta GA 30308 buildings honeywell com 31 00456 02 07 21 ...

Reviews: