11 - 3
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual Trigger
Mode by scanning a Manual Trigger Mode bar code (
), or by sending a serial menu command for triggering (
Once the scanner is in serial trigger mode, the trigger is activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate:
SYN U CR
The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been
reached (see "Read Time-Out" on page 3-5 for a description, and the serial command on
Resetting the Custom Defaults
If you want the custom default settings restored to your scanner, scan the
Activate Custom Defaults
bar code below. This
resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default
settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings.
The charts on the following pages list the factory default settings for each of the commands (indicated by an asterisk (*) on the
programming pages).
Activate Custom Defaults
Summary of Contents for Vuquest 3330g
Page 1: ...Vuquest 3330g Area Imaging Scanner User s Guide ...
Page 10: ...viii ...
Page 12: ...x ...
Page 40: ...2 24 ...
Page 62: ...3 22 ...
Page 80: ...5 14 ...
Page 134: ...7 50 ...
Page 150: ...9 2 Denmark 8 9 6 Norway 8 9 6 Spain 6 Country Codes ...
Page 152: ...9 4 ...