80
Vuquest 3320g User Guide
If this bar code is read,
the next data format, if there is one, will
be used on the data. If there is no other format, the format fails and the raw data is
output as
AB1234
.
If this bar code is read:
the data is output as:
1234AB
<CR>
Check for non-numeric character
ED
Check to make sure there is a non-numeric ASCII character at the current cursor
position. The format is aborted if the character is numeric.
ED Example: Only output the data if the bar code begins with a letter
If you want only data from bar codes that begin with a letter, you can use ED to
check for the letter.
Command string:
EDF10D
ED is the “Check for a non-numeric character” command
F1 is the “Send all characters” command
0D is the hex value for a CR
If this bar code is read,
the next data format, if there is one, will
be used on this data. If there is no other format, the format fails and the raw data is
output as
1234AB
.
If this bar code is read:
the data is output as:
AB1234
<CR>
Insert a delay
EF
Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the
current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms
increments, up to 9999. This command can only be used with keyboard emulation.
Summary of Contents for Vuquest 3330
Page 1: ...User Guide Vuquest 3320g Area Imaging Scanner ...
Page 16: ...xiv Vuquest 3320g User Guide ...
Page 22: ...6 Vuquest 3320g User Guide ...
Page 48: ...32 Vuquest 3320g User Guide ...
Page 100: ...84 Vuquest 3320g User Guide Single Scan Data Format 3 ...
Page 157: ...Vuquest 3320g User Guide 141 InfoMail On ...
Page 180: ...164 Vuquest 3320g User Guide ...
Page 186: ...170 Vuquest 3320g User Guide ...
Page 220: ...204 Vuquest 3320g User Guide ...
Page 224: ...208 Vuquest 3320g User Guide ...
Page 237: ...Vuquest 3320 User Guide 221 Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 239: ......
Page 240: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 3320 UG Rev C 9 17 ...