Vuquest 3320g User Guide
87
External Trigger Parameters
Absolute Maximum
Maxim
u
m Inp
u
t Voltage
Low Value: -0.5 Volts
High Value: +5.5 Volts
The input is protected by an input protection diode
on the ground side.
The input voltage can be below ground provided it is
current limited below the value shown on the next line
of this table.
Maxim
u
m Inp
u
t C
u
rrent
Low Value: -6
Milliamperes
Input protection diode current. The limiting factor on
current is the dissipation in the 1K
, 0402 resistor
(not the gate diode limit).
Parameter Values
Input Resistance to Ground
Low Value: 9.7 K
Nominal Value: 10.0
K
High Value: 10.3 K
Pull down resistor loading.
Maximum Input Low Voltage Logical
Low Level
High Value: 0.8 Volts
Value does not include harness drops or margin for
noise.
Input High Voltage Threshold
Low Value: 2.6 Volts
Value does not include harness drops or margin for
noise.
Summary of Contents for Vuquest 3330
Page 1: ...User Guide Vuquest 3320g Area Imaging Scanner ...
Page 16: ...xiv Vuquest 3320g User Guide ...
Page 22: ...6 Vuquest 3320g User Guide ...
Page 48: ...32 Vuquest 3320g User Guide ...
Page 100: ...84 Vuquest 3320g User Guide Single Scan Data Format 3 ...
Page 157: ...Vuquest 3320g User Guide 141 InfoMail On ...
Page 180: ...164 Vuquest 3320g User Guide ...
Page 186: ...170 Vuquest 3320g User Guide ...
Page 220: ...204 Vuquest 3320g User Guide ...
Page 224: ...208 Vuquest 3320g User Guide ...
Page 237: ...Vuquest 3320 User Guide 221 Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 239: ......
Page 240: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 3320 UG Rev C 9 17 ...